Programación
6.4.2 5-** E/S digital
Par. nº #
Descripción del parámetro
5-0* Digital I/O mode
5-00
Digital I/O mode
5-01
Terminal 27 mode
5-02
Terminal 29 mode
5-1* Digital Inputs
5-10
Terminal 18 digital input
5-11
Terminal 19 digital input
5-12
Terminal 27 digital input
6
6
5-13
Terminal 29 digital input
5-19
Terminal 37 safe stop
5-3* Digital Outputs
5-30
Terminal 27 digital output
5-31
Terminal 29 digital output
5-4* Relays
5-40
Function relay
5-41
On delay, relay
5-42
Off delay, relay
6.4.3 8-** Comunic. y opciones
Par. nº #
Descripción del parámetro
8-0* General Settings
8-01
Control site
8-02
Control word source
8-03
Control word timeout time
8-04
Control word timeout function
8-05
End-of-timeout function
8-06
Reset control word timeout
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC port baud rate
8-33
Parity/stop bits
8-35
Minimum response delay
8-36
Max response delay
8-37
Max inter-char delay
8-4* FC MC Protocol Set
8-42
PCD write configuration
8-43
PCD read configuration
8-5* Digital/Bus
8-53
Start select
8-55
Set-up select
108
Manual de funcionamiento
Valor predeterminado
[0] PNP
[0] Input
[0] Input
[8] Start
[0] No operation
[0] No operation
[0] No operation
[1] Safe Stop Alarm
[0] No operation
[0] No operation
[0] No operation
0.30 s
0.30 s
Valor predeterminado
[0] Digital and ctrl.word
null
1.0 s
[0] Off
[1] Resume set-up
[0] Do not reset
[1] FC MC
2 N/A
[2] 9600 Baud
[0] Even parity, [1] Stop
bit
10 ms
5000 ms
25 ms
[1685] FC port CTW 1
[1603] Status word
[3] Logic OR
[3] Logic OR
Danfoss A/S © Rev. 07-02-2014 Reservados todos los derechos.
4-set-up (4
Cambio
ajustes)
durante
conversión
funciona-
miento
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up (4
Cambio
ajustes)
durante
conversión
funciona-
miento
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Índice de
Tipo
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
Índice de
Tipo
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
Uint8
-3
Uint16
-3
Uint16
-3
Uint16
Uint16
Uint16
-
Uint8
-
Uint8
MG37A205

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido