Wiring Diagram - Sime Brava One BF Manual De Instalación Y Mantenimiento

Calderas murales de baja temperatura
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
1.11

Wiring diagram

BROWN
V
BLUE
BLACK
PI
BLACK
BROWN
L
N
BLUE
CN11
EAR
Line
L
Neutral
N
Fuse (3.15AT)
F
TRA
Ignition transformer
System pump
PI
Fan
V
Ignition / Detection electrode
EAR
EV
Gas supply solenoid valve
Domestic hot water sensor
SS
Dual sensor (thermal safety/delivery)
SM1-2
To connect the "Air Thermostat" or, alternatively the "Remote Control", remove the bridge
between terminals 5-6.
m
CAUTION
Users must:
– Use an omnipolar cut-off switch, disconnect switch
in compliance with EN Standards
– Respect the connections L (Live) - N (Neutral)
– Ensure that the special power cable is only replaced
with a cable ordered as a spare part and connected
by professionally qualified personnel
– Connect the earth wire to an effective earthing
system.The manufacturer is not responsible for any
damage caused by failure to earth the appliance or
failure to observe the information provided in the
wiring diagrams.
VD
2
3
EV
CN12
CN13
CN14
F
CD .6324910
TRA
CR
SE
TA
6
5
4
3
CN15
CN3
CN5
CN6
Flow meter
FLM
Diverter valve
VD
Water pressure switch
PA
TA
Air thermostat
External sensor
SE
Remote control (instead of air thermostat)
CR
d
IT IS FORBIDDEN
To use water pipes for earthing the appliance.
SS
PA
FLM
SM1
SM2
Fig. 6
69