List Of Parameters - Sime Brava One BF Manual De Instalación Y Mantenimiento

Calderas murales de baja temperatura
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
– press the button
>
to scroll up the list of parameters and then
<
to scroll down the list
holding the buttons
>
NOTE:
scrolling movement.
– once the required parameter has been reached, press the
button
o
for approximately 3 seconds to confirm and access
the set value which will then flash and can then be modified
– to modify the value in the permitted range, press the buttons
>
to increase it or
<
to decrease it
– once the required value has been reached, press the button
o
to confirm.
3.4

List of parameters

Type
Nr.
Description
Index showing boiler power in kW
tS
0.1
0 = 24; 1 = 30
Hydraulic configuration
0 = rapid
1 = storage tank with thermostat or heating only
tS
0.2
2 = hot water tank with sensor
3 = two programmer
4=instant with solar power input
Gas Type Configuration
tS
0.3
0 = G20; 1 = G31
Combustion configuration
0 = sealed chamber with combustion control
tS
0.4
1 = open chamber with smoke thermostat
2 = low NOx
tS
0.7
Ignition power
tS
0.8
External sensor value correction
tS
1.0
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
tS
1.1
-- = Disabled
tS
1.2
Heating Curve Incline
tS
1.3
Minimum Heating Temperature Adjustment
tS
1.4
Maximum Heating Temperature Adjustment
tS
1.5
Maximum power heating
tS
1.6
Heating Post-Circulation Time
tS
1.7
Heating Pump Activation Delay
tS
1.8
Re-ignition Delay
Domestic Hot Water Modulation with Flow meter
tS
1.9
0 = Disabled
1 = Enabled
tS
2.0
Maximum power domestic hot water
tS
2.1
Minimum power heating/domestic hot water (premixed)
Domestic hot water preheating enabling
tS
2.2
0 = OFF; 1 = ON
tS
2.5
Internal parameter (no change)
tS
2.6
Zone Valve / Pump Relaunch Delay
or
<
increases the speed of the
CONFIGURATION
DOMESTIC HOT WATER - HEATING
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
and
o
for approximately 5 seconds until the
at the same time
initial screen is displayed.
Range
0 .. 1
0 .. 4
0 .. 1
0 .. 2
0 .. 40
-5 .. +5
0 .. +10
-9 .. +5
0 .. 80
20 .. Par tS 1.4
Par tS 1.3 .. 80
0 .. 100
0 .. 99
0 .. 60
0 .. 60
0 .. 1
0 .. 100
0 .. 100
0 .. 1
-
0 .. 99
U/M
Step
Default
-
1
0 or 1
-
1
0
-
1
0 or 1
-
1
0
-
1
0
°C
1
0
°C
1
3
°C
1
-2
-
1
20
°C
1
20
°C
1
80
%
1
100
seconds
1
3
x 10
seconds
1
0
x 10
Min
1
3
-
1
1
%
1
100
%
1
0
-
1
0
-
-
0
Min
1
1
<
81

Publicidad

Tabla de contenido
loading

Tabla de contenido