General Features - Sime OPEN.zip 25 BF TS Instrucciones Para El Instalador

Ocultar thumbs Ver también para OPEN.zip 25 BF TS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- In the case of breakdown or faulty functioning of the appliance, switch it off and make no attempt whatsoever to repair it, and do not pro-
ceed with any direct intervention.
- Apply only to authorised technical personnel. Installation of the boiler or any other assistance or maintenance work must be carried out
by qualified personnel. Tampering with devices sealed by the constructor is absolutely forbidden.
- Obstructing the aspiration grills and the air vents of the room where the appliance is installed is asolutely forbidden.
- The constructor shall not be responsible for any damages deriving from incorrect use of the appliance.
REMOTE CONTROL 582 HRC

GENERAL FEATURES

Wall installation is foreseen although the
device for battery pack replacement can be
removed.
INSTALLATION
1) The remote control panel must be
installed at a height of about 1.5 meters
from the ground, as far as possible from
heat sources and from doors and/or
windows. There is a special hole at the
back of the adapter base for connection
of the electric wires.
IMPORTANT: Switch off power to the
plant before connecting the wires.
2) Remove the adaptor from the remote
control panel, by pressing with the fin-
gers on the crescent shaped part (fig. 2).
3) Unscrew the two screws on the adaptor
and fix the lower shell of the same to the
wall.
4) Connect the terminal block to the adap-
tor, taking care to follow the diagram in
fig. 4. The connections are not polarised.
5) Insert the batteries into the special com-
partment in the back of the remote con-
trol panel.
6) Using a ball point pen, press the button
(reset) on the front of the control panel,
accessible by opening the lower hatch.
7) Close the adaptor cover and apply the
terminal of the remote control panel to
it (fig. 3).
USER'S INSTRUCTIONS
TECHNICAL DATA
Protection degree
Maximum overall dimensions (mm)
LCD area visible LCD (mm)
Power supply voltage
Buffer batteries
Working temperature range (°C)
Storage temperature range (°C)
Humidity
Back-up autonomy
Use
Connection
Reading resolution
Maximum reading error
Setting regulation range (°C)
Min. regulation range (°C)
Data updating interval
Monitoring/control interval
Fig. 2
NO
WARNINGS
IP20 (in the case of wall installation)
L=132 x H=105 x P=43
83 x 55
24 Vdc
4 alkaline pen batteries LR6 AA - 1.5V
0 ÷ 40
10°C ÷ 50°C
max 95 % at 40°C
≥ 1 year
in sunlight/artificial light
max 20 m
0. 1 °C between 0°C and 40°C
1°C between 0°C and 40°C
5 ÷ 30
0 ÷ 25
1s
1s
YES
Fig. 1
Fig. 3
67