Sime Murelle EV HE Serie Manual Del Usuario página 97

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.3
ACCESS TO
INSTALLER'S
PARAMETERS
For access to the installer's parameters,
press simultaneously the keys
or 5 seconds (3 fig. 12).
For example, the parameter PAR 23 is
visualised on the display of the control
panel in the following way:
The paramet er s scr oll for war ds and
backwards with the key
and
the default parameters can be changed
with the keys
and
.
The standard visualisation returns automa-
tically after 60 seconds, or by pressing one
of the control keys (2 fig. 12).
3.3. 1
Replacing the board or
RESETTING parameters
If the electronic board is replaced or reset,
it is necessary to configure PAR 1 and PAR
2 by associating the following values to
each type of boiler to be able to restart the
boiler:
GAS
MODELS
12 T
METHANE
20 T
(G20)
25 - 25 T
30 - 30 T
35 - 35 T
12 T
20 T
-
PROPANE
25 - 25 T
(G31)
-
30 - 30 T
35 - 35 T
FAST CONFIGURATION
and
PAR DESCRIPTION
1
Combustion configuration
2
Hydraulic configuration
3
Timetable 2 programmer
4
Pressure transducer disabler
and
5
Assignment of auxiliary relay AUX
(D.H.W. tank)
6
Luminous bar indicating presence
of voltage
7
Allocation of CR73 channels
8
Fan rpm Step ignition
9
Long chimneys
10 Remote control option setting
11 Correction values external sensor
12 Backlighting duration
PAR 1
1
13 Modulating pump speed
2
3
4
5
D.H.W. - HEATING
6
PAR DESCRIPTION
7
20
D.H.W. minimum temperature
8
21
D.H.W. maximum temperature
9
22
Anti-legionella (only D.H.W. tank)
10
11
23
Boiler antifreeze
12
24
External sensor antifreeze
25
Climatic curve setting Zone 1
26
Climatic curve setting Zone 2
27
Minimum temperature Zone 1
28
Minimum temperature Zone 1
29
Minimum temperature Zone 2
30
Maximum temperature Zone 2
31
Maximum heating power
32
C.H. post-circulation time
33
Pump activation delay Zone 1
34
Re-ignition delay
35
Integrative sources activation threshold -- , 15 ... 80
36
D.H.W. post-circulation time
39
Saturation zone modulation
D.H.W. flowmeter
PARAMETERS INSTALLER
RANGE
UNIT OF
MEASUREMENT
-- = ND
1 ... 30
-- = ND
1 ... 9
1 = DHW + Recirc. pump
2 = DHW
3 = Recirculation pump
0 = Disabled
1 = Enabled
2 = Enabled (NO ALL 09)
1 = Remote supply
2 = Recirculation pump
0 = Disabled
1 = Enabled
0 = Not assigned
1 = Circuit 1
2 = Circuits 1 and 2
0,0 ... 81
rpmx100 0, 1 da 0, 1 a19,9
0 ... 20
1 = CR 73
2 = CR 53
3 = RVS
-5 ... +5
-- = Always
0 = Never
sec. x 10
1 ... 199
0 = Minimum
1 = Maximum
2 = Automatic
RANGE
UNIT OF
MEASUREMENT
10 °C ... PAR 21
PAR 20 ... PAR 62 OEM
0 = Disabled
1 = Enabled
0 ... +20
- 15 ... +5
3 ... 40
3 ... 40
PAR 64 OEM ... PAR 28
PAR 27 ... PAR 65 OEM
PAR 64 OEM ... PAR 30
PAR 29 ... PAR 65 OEM
30 ... 100
0 ... 199
0 ... 199
0 ... 10
0 ... 199
-- = Enabled
0 ... 100
INC/DEC
DEFAULT
UNIT
SETTING
=
=
"--"
=
=
"--"
=
=
1
=
=
1
=
=
1
=
=
1
=
=
1
0,0
1da 20 a 81
%
1
0
=
=
1
°C
1
0
1
3
=
=
1
INC/DEC
DEFAULT
UNIT
SETTING
°C
1
30
°C
1
60
=
=
0
°C
1
3
°C
1
- 2
=
1
20
=
1
20
°C
1
20
°C
1
80
°C
1
20
°C
1
80
%
1
100
Sec.
10
30
10 sec.
1
1
Min.
1
3
°C
1
"--"
Sec.
1
0
%
1
100
ES
PT
ENG
97