Brita PROGUARD Coffee Manual De Instrucciones página 60

Ocultar thumbs Ver también para PROGUARD Coffee:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 211
• Flushing of the mineralisation cartridge PURITY C500 MinUp
Step
• Connection of the enclosed flushing head to the membrane cartridge
#3
PURITY C150 PROGUARD
• Flushing of the post-filter cartridge PURITY C50 Fresh
Detachment of the mineralisation cartridge from the pre-filter head:
• After being sufficiently flushed, close the flush valve of the pre-filter head by pushing
the grey slider inwards
• Open the locking handle of the pre-filter head by bringing its two blue handles in an
inclined position. Do not close the shutoff valve!
• Open the flush valve of the pre-filter head to release the remaining inner pressure of the
cartridge by pushing the grey slider on the pre-filter head outwards. Catch the coming out
water with the bucket
• Close the flush valve of the pre-filter head and pull the pre-filter head off the cartridge
3.4
• Insert the post-filter into the pre-filter head.
• Close the pre-filter head's locking handle by bringing its two blue handles in a horizontal
position
• Make sure that the pre-filter head's bypass is set to 0 % (Allen key size 4 mm)
EN
• Place a bucket close to the cartridge (~10 litres) and hang the cartridge's grey flushing
hose into the bucket
• Flush the post-filter cartridge: Open the pre-filter head's flush valve by pushing the grey
slider outwards. Flush 2 bed volumes
Size of post-filter
PURITY C50 Fresh
3.5
60
1 x bed volume (in litre)
1
0 %
1
2
2x bed volume (in litre)
2
2x

Publicidad

Tabla de contenido
loading

Tabla de contenido