• Flushing of the membrane cartridge PURITY C150 PROGUARD
Step
• Connection of the waste water tube
#5
• Connection of the FlowMeter
Use the other of the two self-selected hoses (step 1.5) to connect the G 3/8" male thread
of the post filter with the coffee machine's water inlet connection
5.5
After 30 minutes flushing, detachment of the flushing head from the membrane
cartridge PURITY C150 PROGUARD:
• Shut the flushing head valve
• Open the locking handle of the flushing head by bringing its two blue handles in
an inclined position
• Wait until the remaining water that is still coming out of the flushing head's two tubes
has ceased to flow. This can take up to 5 minutes. Alternatively, you can immediately
pull-off the flushing head to speed up the process, resulting in water splashing out of the
cartridge.
5.6
Use DMfit's collet locking tool to push-back the collet of the flushing head valve and pull the
flushing head's tube off
5 min.