Step
Flushing of the PROGUARD Coffee system
#6
Insertion of the membrane cartridge and the mineralisation cartridge into the firmly
mounted filter heads of PROGUARD Coffee:
• Insert the PURITY C150 PROGUARD cartridge (left side) and the PURITY C500 MinUp
cartridge (right side) into their respective filter head
• Close the filter heads' locking handles by bringing the two blue handles in a horizontal
position respectively
• As a result, a regular click-sound made by the non-electric pump should be noticeable.
PROGUARD Coffee is now put into operation
• Within the next minutes, the pressure indicating needle of the manometer should
gradually move upwards into the green range
6.2
Bleeding of PROGUARD Coffee:
• Wait until the pressure needle of the manometer shows a value of at least 2 bar
• Insert the 25cm black tube into the bleed valve
• Place a bucket under the tube and open the bleed valve until the effluent is clear of
any air bubbles
≥2
6.3
2x
1
2