Use And Functioning; Description Of The Functioning Cycles - Diamond DBT102/L Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.

USE AND FUNCTIONING

5.1.

Description of the Functioning Cycles

The following are brief descriptions and types of
operating cycles.
Temperature Blast Chilling
This cycle allows a reduction in temperature in the
product core from +90°C to +3°C as quickly as
possible and within a MAX time of 90 minutes.
The cycle ends when the value +3°C, read by the
needle probe, is reached.
Time Blast Chilling
This cycle allows a reduction in temperature in the
product core from +90°C to +3°C during the set
time: we remind you that it is advisable to run
some previous testing temperature cycles in order
to determine the necessary time for a correct
product blast chilling process. Do not forget that
acquired times have to be considered valid for
exclusive use of the same type of product and in
the same quantities per cycle.
Temperature Shock Freezing
This cycle allows a reduction in temperature in the
product core from +90°C to -18°C
quickest time possible and within a MAX time
equal to 270 minutes. The cycle ends when the
value -18°C, read by the needle probe, is
reached.
Time Shock Freezing
This cycle allows a reduction in temperature in the
product core from +90°C to -18°C during the set
time: we remind you that it is advisable to run
some previous testing temperature cycles in order
to determine the necessary time for a correct
product blast chilling process. Do not forget that
acquired times have to be considered valid for
exclusive use of the same type of product and in
the same quantities per cycle.
Preservation
At the end of each cycle as described above,
either temperature or time cycle, the preservation
cycle will be started automatically, with no time
limit. The freezer temperature will refer to last
cycle, just concluded:
 + 3°C for blast chilling
 -25°C for shock-freezing
Warning: use of this cycle is recommended only
for short periods prior to storage of the product in
a storage unit or in case of emergency, so as to
avoid such a limited use of a machine with such
high potential.
Defrosting
The frost forming on the evaporator following the
deposit of humidity from the product can
jeopardise
appliance. A defrosting cycle must be carried out
in
the
to restore full functionality.
Defrosting is performed by forced ventilation using
the evaporator fan. The cycle can be performed
with the door open or closed and can also be
interrupted at any time.
7
ENGLISH
the
correct
functioning
GB
of
the

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abv4042

Tabla de contenido