7.1. Faults Display

Problem
"E0" flashes on the display and
the buzzer emits an intermittent
(compartment probe error)
"E1" flashes on the display and
the buzzer emits an intermittent
GB
(evaporator probe error)
"E3" flashes on the display and
the buzzer emits an intermittent
(needle probe error)
"dFL" flashes on the display and
the buzzer emits an intermittent
"HP" flashes on the display and
the buzzer emits an intermittent
(high pressure- Compressor
Circuit Breaker alarm)
8.

INSTALLATION

8.1.

Packaging And Unpacking

Handle and install the appliance respecting the
information provided by the manufacturer, shown
directly on the packaging, on the appliance and in
this manual.
The lifting and transportation system of the
packaged product envisions the use of a fork-lift
truck or a pallet stacker. When using these,
particular attention must be paid to balancing the
weight in order to prevent the risk of overturning
(avoid excessive tilting!).
!
ATTENTION: When inserting the lifting
device, pay attention to the power supply cable
and the position of the feet.
ENGLISH
noise
 The type of probe is
 The probe is faulty.
 The probe – circuit board
noise
 The temperature detected
noise
The evaporator fan deflector
has been opened.
noise
 The pressure detected by
noise
 The absorption of the
Causes
incorrect.
connection is incorrect.
by the probe is out of the
limits accepted by the
compartment probe in use
the
maximum
pressure
switch is higher than the
limit value.
compressor has exceeded
the envisioned maximum
limit.
The packaging is made of cardboard and the
pallet of wood. A series of symbols is printed on
the cardboard packaging which highlights, in
accordance with international standards, the
provisions to which the appliances are subjected
during loading, unloading, transport and storage.
TOP
18
Solutions
Contact the after-sales
centre.
 Check that the compartment
probe is the PTC type.
 Check the integrity of the
compartment probe.
 Check correctness of the
instrument - probe connection.
 Check that the temperature in
proximity of the compartment
probe is not out of the accepted
limits
Close the evaporator fan deflector.
If the problem persists,
contact the after-sales centre.
 Air the environment.
 Clean the condenser
 Check that the fans function
correctly.