2.3.9 EXPERT MODE. ADVANCED MENU
1. Enter the EXPERT Mode option in the Settings Menu to access the advanced menu settings..
2. Browse, select and set the options and settings in the advanced menu by using the Arrow Buttons (
3. Press button
(Enter) button to confirm the setting made or press button
5
the options in the Settings Menu.
OPTIONS IN THE ADVANCED SETTINGS MENU:
1.0
SETTINGS
EXPERT
MODE
Advanced
settings
HMI VICTORIA PLUS SILENT VS CONTROL PANEL -
1.0.1
Low
Setpoint
1.0.2
Medium
Setpoint
1.0.3
High Setpoint
1.0.4
ID_ADDRESS
1.0.5
COM_SETUP
1.0.6
Brightness
(0–10)
1.0.7
AUTO settings
1.0.8
Self-priming
Speed
1.0.9
Self-priming
time
INSTRUCTION MANUAL
(Exit) button to go back to
4
Configuration of the Setpoint modes, equivalent to the
SETPOINT option in the Settings Menu.
Configuration of the setpoint, equivalent to the SETPOINT
option in the Settings Menu.
Configuration of the setpoint, equivalent to the SETPOINT
option in the Settings Menu.
Configuration of the ID_ADDRESS: (0-255)
21 (Default Value)
0: 9600, 8, E, 1 (Default Value)
1: 19200, 8, E, 1
Communication
2: 9600, 8, N, 2
protocols:
3: 19200, 8, N, 2
4: 9600, 8, N, 1
5: 19200, 8, N, 1
Selection of the screen's brightness
0: Brightness off up to 10 Maximum brightness
MIN: AUTO settings in minutes
HOUR: AUTO settings in hours
Self-priming Speed settings
Minimum: 1,000 rpm up to the Maximum: 3,135 rpm
Self-priming settings in seconds: Minimum 0 seconds up to
the Maximum: 300 seconds
0 seconds: A specific Self-priming command is not carried out
).
10