2.2 AUTO MODE
In AUTO Mode, the pump automatically runs a weekly programmable timer set by the user for which the
desired Setpoint Speeds must be configured.
To run in AUTO Mode, it is essential to configure the Day and Time under the CLOCK and DAY
options in the Settings Menu (see Sections 2.1.1 CLOCK and 2.1.2 DAY).
The timer will be programmed based on each pool (energy savings, total water volume, etc.) and the times it
is normally used.
To run the pump in AUTO Mode, press button
current day of the week.
To cancel the AUTO Mode, either press button
pump into Manual Mode.
Whenever the pump is started up in MANUAL Mode, it will self-prime for 30 seconds at a speed of 2,850 rpm
by default. The default self-priming time and speed can be adjusted, and can also be disabled from
the EXPERT Mode in the Settings Menu (see Section 2.3.9). While it is self-priming, the speed reading will
flash on and off until the process has been completed.
If the pump is running in MANUAL Mode and the AUTO Mode is enabled, it will work according to the
automatic timer settings.
To display and configure the timer for the whole week, go to the TIMER option in the Settings Menu (Section 2.3.8).
If you wish to configure the Setpoint Speeds, go to the SETPOINT option in the Settings Menu (Section 2.3.5).
ENABLING AUTO MODE:
STANDBY MODE
Auto
2
Current day of the week
HMI VICTORIA PLUS SILENT VS CONTROL PANEL -
(AUTO). The screen will show the timer settings for the
2
(On/Off) to enable the STANDBY Mode or to put the
1
Operating mode:
AUTO Mode on
INSTRUCTION MANUAL
®
Setpoint
Operating
Modes
Time slots