1.1
EXPERT
MODE
SERIAL
1.2
HWSW
1.3
ALARM
1.4
WARNING
1.5
CONNE
24
1.1.1
Displays the first part of the Serial Number
1.1.2
Displays the second part of the Serial Number
1.2.
Displays the software version of the Control Panel
1.2.2
Displays the hardware version of the Control Panel
1.2.3
Displays the software version of the Inverter
1.2.4
Displays the hardware version of the Inverter
The codes of enabled Alarms are displayed. If there is more than one Alarm, the letter
"M" will appear in front (multiple Alarms).
The pump will not start up if an Alarm goes off
LIST OF ALARMS:
A001: Motor blocked
A002: Open phase
A003: Short circuit between phases. IGBT module damaged
A004: Mains supply below minimum voltage required
A005: Mains supply above maximum voltage allowed
A006: Power surge
A007: Temperature too high
A008: EEPROM error
A011: Overheated motor
A012: Overheated IGBT
The codes of enabled Warnings are displayed. If there is more than one Warning, the
letter "M" will appear in front (multiple Warnings).
The pump can be switched on even if there is a Warning.
List of Warnings:
W001: Temperature too high
W002: Communication between the Display and Inverter
W005: The SETPOINT cannot be reached
Configures the Connection settings
ID_Address:
H0x0015 (Default Value)
COM_Setup:
H0x0100 (Default Value)
Watchdog_Time:
H0x1000 (Default Value)
HMI VICTORIA PLUS SILENT VS CONTROL PANEL -