Standby Mode - Astralpool VICTORIA PLUS SILENT VS Manual De Instrucciones

Ocultar thumbs Ver también para VICTORIA PLUS SILENT VS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
2.1.1 MANUAL MODE WITH SETPOINT SPEED
The pump has 4 Setpoint Speeds in MANUAL Mode: Low, Medium, High and Turbo.
Turbo Speed is normally used for fast cleaning and is pre-set by the manufacturer to last 10 minutes. Once
this time is over, the pump will automatically run in MANUAL Mode at High Speed. The speed and duration
of the Turbo Speed cannot be changed for safety reasons.
The Low, Medium and High setpoint operating speeds can be configured from the SETPOINT option on the
Settings Menu (see Section 2.1.5) or from the EXPERT MODE option in the Settings Menu (see Section 2.1.9).
Use the following sequences for running the pump in MANUAL Mode with a Setpoint Speed:

STANDBY MODE

AUTO MODE
MANUAL MODE
Rpm reading flashes during self-priming start-up phase
Low Speed start-up
Medium Speed start-up
High Speed start-up
Turbo Speed start-up
(1,400 rpm by default)
(2,100 rpm by default)
(2,750 rpm by default)
(3,025 rpm by default)
Turbo Speed mode ended (10 min by default)
The Setpoint Speed can be changed by pressing the Up Arrow to increase it and the Down Arrow to decrease
it. By pressing it for a short interval, it increases by 25 rpm and by pressing it for long intervals (>3s) it
increases non-stop until the button is released.
HMI VICTORIA PLUS SILENT VS CONTROL PANEL -
INSTRUCTION MANUAL
7

Publicidad

Tabla de contenido
loading

Tabla de contenido