usable.height.of.the.water.trap.must.be.at.
least.150.mm.
2.7 
FORCED EXHAUST 
TYPE B23P - B53P 
(fig. 9/a)
This. type. of. exhaust. pipe. is. installed. using.
the. special. kit,. code. 8089912/13.. For. kit.
assembly. instructions,. refer. to. point. 2.6..
Protect. the. intake. with. the. optional. acces-
sory,.code.8089501..
The.accessory.is.assembled.by.cutting.a.50.
mm. long. segment. from. an. ordinary. ø. 80.
extension. and. inserting. it. on. the. air. intake,.
on.which.the.accessory.is.then.fitted,.ancho-
red. to. the. pipe. segment. with. the. screws.
provided.(fig..9/a)...
Maximum flow resistance must be no more 
than 10 mm H
O (version 12) - 15 mm H
2
(version  25-30-35)  (ATTENTION:  the  total 
length of each pipe should not exceed 25 m, 
even if the total loss is below the maximum 
applicable loss.)
As. the. maximum. pipe. length. is. determi-
ned. by. adding. up. the. flow. resistance. of.
the.various.individual.accessories.installed,.
refer.to.Table 1-1/a.for.calculation.
2.8 
POSITIONING THE 
OUTLET TERMINALS (fig. 10)
The. outlet. terminals. for. forced-draught.
TABLE 3
Siting.of.terminal.
. . .
A. -. below.openable.window.
B. -. below.ventilation.opening.
C. -. below.eaves.
D. -. below.balcony.(1).
E. -. from.adjacent.window.
F. -. from.adjacent.ventilation.opening.
G. -. from.horizontal.or.vertical.soil.or.drain.pipes.(2).
H. -. from.corner.of.building.
I. -. from.recess.in.building.
L. -. from.ground.level.or.other.treadable.surface.
M. -. between.two.terminals.set.vertically.
N. -. between.two.terminals.set.horizontally.
O. -. from.a.surface.facing.without.openings.or.terminals. 2000
P. -. as.above.but.with.openings.and.terminals.
1). Terminals. below. a. practicable. balcony. must. be. located. in.
such. a. way. that. the. total. path. of. the. smoke. from. its. outlet.
point.from.the.terminal.to.its.outlet.point.from.the.external.
perimeter. of. the. balcony,. including. the. height. of. possible.
railings,.is.not.less.than.2000.mm.
2). When.siting.terminals,.where.materials.that.may.be.subject.
to.the.action.of.the.combustion.products..are.present.in.the.
vicinity,.e.g.,.eaves,.gutters.and.downspouts.painted.or.made.
of.plastic.material,.projecting.timberwork,.etc.,.distances.of.
not. less. than. 1500. mm. must. be. adopted,. unless. adequate.
shielding.is.provided.to.guard.these.materials.
appliances. may. be. located. in. the. external.
perimeter.walls.of.the.building..
To.provide.some.indications.of.possible.solu-
O 
2
tions,.Table 3.gives.the.minimum.distances.
to.be.observed,.with.reference.to.the.type.of.
building.shown.in.fig..10.
2.9 
ELECTRICAL 
CONNECTION
The.boiler.is.supplied.with.an.electric.cable..
Should.this.require.replacement,.it.must.be.
purchased.exclusively.from.SIME..
The.electric.power.supply.to.the.boiler.must.
be.230V.-.50Hz.single-phase.through.a.fused.
main. switch,. with. at. least. 3. mm. spacing.
Appliances.from.7.to.35.kW
(distances.in.mm)
600
600
300
300
400
600
300
300
300
2500
1500
1000
3000
cod. 8089501
between.contacts..
Respect.the.L.and.N.polarities.and.the.earth.
connection.
NOTE:  SIME  declines  all  responsibility  for 
injury  or  damage  to  persons,  animals  or 
things, resulting from the failure to provide 
for proper earthing of the appliance.
2.9.1 
Chronothermostat  connection
Connect. the. chronothermostat. as. indicated.
in.the.boiler.electrical.diagram.(see figs. 11 
e 
11/a) 
after. having. removed. the. existing.
bridge..
The. chronothermostat. to. be. used. must. be.
ES
PT
ENG
Fig..9/a
Fig..10
85