Remote Control - Sime Murelle HE 12 T ErP Instrucciones Originales

Ocultar thumbs Ver también para Murelle HE 12 T ErP:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

of. a. class. conforming. to. the. standard. EN.
607301.(clean.electrical.contact).
2.9.2 
Remote control 
SIME HOME
connection (optional)
The. boiler. is. designed. for. connection. to. a.
remote. control. unit,. supplied. on. request.
(SIME.HOME.code.8092280/81).
The.remote.control.SIME.HOME.unit.allows.
for.complete.remote.control.of.the.boiler..
The. boiler. display. will. show. the. following.
message:
For.installation.and.use.of.the.remote.con-
2.9.5 
Use with different 
electronic systems
Some.examples.are.given.below.of.boiler.
systems.combined.with.different.electro-
nic.systems..Where.necessary,.the.para-
meters.to.be.set.in.the.boiler.are.given..
The. electrical. connections. to. the. boiler.
refer. to. the. wording. on. the. diagrams.
(figg.. 11-11/a).. The. zone. valve. control.
starts.at.every.demand.for.heating.of.the.
zone. 1. (it. is. from. part. of. the. TA1. or. the.
CR)..Description.of.the.letters.indicating.
the. components. shown. on. the. system.
diagrams.from.1.to.14:
M.
C.H..flow
R.
C.H..return
CR.
Remote.Control.
.
SIME.HOME.code.8092280/81
SE.
External.temperature.sensor
TA.1-2-3-4. Zone.room.thermostat
CT.1-2.
Zone.chronothermostat
VZ.1-2.
Zone.valve
RL.1-2-3-4. Zone.relay
Sl.
Hydraulic.separator
P.1-2-3-4. Zone.pump
SB.
D.H.W..sensor
PB.
D.H.W..pump
IP.
Floor.system
EXP.
Expansion.card.ZONA.MIX.(code
..
8092234)/INSOL.
.
(code.8092235)
VM.
Three-way.mixer.valve
86
trol,.follow.the.instructions.in.the.package.
NOTE: Ensure PAR 10 set to 1 (PAR 10 = 1).
2.9.3 
External sensor connection
The. boiler. is. designed. for. connection. to. an.
external. temperature. sensor,. supplied. on.
request. (code. 8094101),. which. can. auto-
matically.regulate.the.temperature.value.of.
the. boiler. output. according. to. the. external.
temperature..
For.installation,.follow.the.instruction.in.the.
package.. It. is. possible. to. make. corrections.
to.the.values.read.by.the.drill.acting.on.the.
PAR 11.
2.9.4 
D.H.W. sensor connection 
in vers. "12-25-30-35 T ErP"
The."12-25-30-35 T ErP".version.is.provided.
with.a.D.H.W..sensor.(SB).linked.to.the.con-
nector.CN5.
1 
BASIC SYSTEM
SYSTEM WITH A DIRECT ZONE AND ROOM THERMOSTAT, OR WITH 
REMOTE CONTROL SIME HOME (Code 8092280/81) AND EXTERNAL 
SENSOR (Code 8094101)
CR
SE
CR
SE
TA1
M
TA
When. the. boiler. is. coupled. to. an. external.
boiling. unit,. introduce. the. sensor. into. the.
special.sleeve.in.the.boiling.unit.
ATTENTION: The "T" version is designed for 
connection to a remote boiling unit, for use 
ONLY FOR HEATING it is necessary:
-  to disconnect the D.H.W. sensor (SB);
-  set PAR 2 and 4.
Operations must be carried out by authori-
zed and qualified technicians.