INSTALLATION

The.boiler.must.be.installed.in.a.fixed.loca-
tion. and. only. by. specialized. and. qualified.
firms. in. compliance. with. all. instructions.
contained. in. this. manual.. Furthermore,. the.
installation.must.be.in.accordance.with.cur-
rent.standards.and.regulations..
2.1 
INSTALLATION
–.. Boilers. can. be. installed. in. all. domestic.
environments. without. any. whatsoever.
limit. in. terms. of. location. and. comburent.
air.supply.
–.. These.boilers.can.also.be.installed.in.par-
tially.covered.areas,.as.per.EN.15502,.with.
a.maximum.ambient.temperature.of.60°C.
and. a. minimum. ambient. temperature. of.
-5°C.. It. is. generally. advisable. to. install.
the.boilers.below.weathered.roofs,.on.the.
balcony.or.in.a.protected.niche,.to.protect.
them.from.exposure.to.weathering.agents.
(rain,.hail.and.snow)..All.boilers.provide.a.
standard.antifreeze.function..
2.1.1 
Anti-freeze function
The. boilers. are. equipped. with. anti-freeze.
function. which. activates. the. pumps. and.
the. burner. when. the. temperature. of. the.
water. contained. inside. the. appliance. drops.
to. below. 6°C.. The. anti-freeze. function. is.
ensured,.however,.only.if:
-. the. boiler. . is. correctly. connected. to. the.
gas.and.electricity.supply.circuits;
-. the.boiler.is.constantly.fed;
-. the.boiler.ignition.is.not.blocked;
-. the.essential.components.of.the.boiler.are.
all.in.working.order.
In. these. conditions. the. boiler. is. protected.
against.frost.down.to.an.environmental.tem-
perature.of.-5°C.
ATTENTION: In the case of installation in a 
place  where  the  temperature  drops  below 
0°C,  the  connection  pipes  must  be  pro-
tected. 
2.2 
COMPLEMENTARY ACCESSORIES
To.simplify.connections.to.the.hydraulic.and.
gas. supplies,. it. is. also. possible. to. use. the.
following.accessories:
–. Mounting.plate,.code.8081220
–. Kit..with.bends,.code.8075423
–. Kit.with.faucets,.code.8091806
–. Kit.with.faucets.boiler.T,.code.8091820
–. Kit.for.the.replacement.of.wall-mounting.
assemblies.of.other.manufacturers,.code.
8093900
–. Solar. kit. for. the. instantaneous,. code.
8105101,.in.coupling.to.kit.INSOL
–. Mixed.area.kit.ZONA.MIX,.code.8092234
–. Solar. kit. INSOL. only. for. heating. boilers,.
code.8092235
–. Antifreeze. heaters. kit. -15°C,. code.
8089806.
For. detailed. information. on. the. assembly.
of. fittings,. see. the. instructions. contained.
in.the.box.
2.3 
CONNECTING UP SYSTEM
To. protect. the. heat. system. from. damaging.
corrosion,. incrustation. or. deposits,. befo-
re. installation. it. is. extremely. important. to.
clean. the. system. using. suitable. products.
such. as,. for. example,. Sentinel  X300  (new 
system),  X400  and  X800  (old  system)  or 
Fernox  cleaner  F3.. Complete. instructions.
are.provided.with.the.products.but,.for.fur-
ther. information,. you. may. directly. contact.
SENTINEL.PERFORMANCE.SOLUTIONS.LTD.
or.FERNOX.COOKSON.ELECTRONICS.
For. long-term. protection. agains. corrosion.
and. deposits,. the. use. of. inhibitors. such. as.
Sentinel  X100  or  Fernox  protector  F1. is.
recommended. after. cleaning. the. system.. It.
is. important. to. check. the. concentration. of.
the. inhibitor. after. each. system. modifica-
tion. and. during. maintenance. following. the.
manufacturer's. instructions. (specific. tests.
are. available. at. your. dealer).. The. safety.
valve. drain. must. be. connected. to. a. collec-
tion. funnel. to. collect. any. discharge. during.
interventions.. If. the. heating. system. is. on. a.
higher.floor.than.the.boiler,.install.the.on/off.
taps. supplied. in. kit. optional. on. the. heating.
system.delivery/return.pipes..
WARNING: Failure to clean the heat system 
or add an adequate inhibitor invalidates the 
device's warranty.
Gas.connections.must.be.made.in.accordan-
ce. with. current. standards. and. regulations..
When. dimensioning. gas. pipes. from. the.
meter. to. the. module,. both. capacity. volume.
(consumption).in.m
3
/h.and.gas.density.must.
be.taken.into.account..
The. sections. of. the. piping. making. up. the.
system.must.be.such.as.to.guarantee.a.sup-
KEY
. 1. Diverter.valve.(VD)
. 2. D.H.W..sensor.(SS)
. 3. D.H.W..exchanger.with.plates.
. 4. Water.pressure.transducer.(TPA)
. 5. Air.release.vent
ply. of. gas. sufficient. to. cover. the. maximum.
demand,.limiting.pressure.loss.between.the.
gas.meter.and.any.apparatus.being.used.to.
not.greater.than:
–. 1.0.mbar.for.family.II.gases.(natural.gas);
–. 2.0. mbar. for. family. III. gases. (butane. or.
propane).
An.adhesive.data.plate.is.sticked.inside.the.
front.panel;.it.contains.all.the.technical.data.
identifying.the.boiler.and.the.type.of.gas.for.
which.the.boiler.is.arranged.
2.3.1 
Connection of condensation 
water trap
The. drip. board. and. its. water. trap. must. be.
connected.to.a.civil.drain.through.a.pipe.with.
a.slope.of.at.least.5.mm.per.metre.to.ensure.
drainage.of.condensation.water..
The  plastic  pipes  normally  used  for  civil 
drains  are  the  only  type  of  pipe  which  is 
appropriate  for  conveying  condensation  to 
the building's sewer pipes.
2.3.2 
Filter on the gas pipe
The.gas.valve.is.supplied.ex.factory.with.an.
inlet. filter,. which,. however,. is. not. adequate.
to. entrap. all. the. impurities. in. the. gas. or. in.
gas.main.pipes..
To.prevent.malfunctioning.of.the.valve,.or.in.
certain.cases.even.to.cut.out.the.safety.devi-
ce. with. which. the. valve. is. equipped,. install.
an.adequate.filter.on.the.gas.pipe.
2.4 
SYSTEM FILLING (fig. 4)
Filling.of.the.boiler.and.the.system.is.done.by.
the.system.filling.(11)..The.charge.pressure,.
. 6. Pump.high.efficiency.(PI)
. 7. Boiler.discharge
. 8. 3.BAR.safety.valve
. 9. D.H.W..filter
10. . D.H.W..flowmeter.sensor