Electrical Connection - Sime Format Instrucciones Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

KEY
1 Tile with articulated joint
2 Lead panel
3 Collar
4 Locking screw
5 Reducing fitting
with gasket
2.9
FORCED OUTLET
The "25 BF" version can also be installed as
a B
type apparatus by assembling the
22
stub pipe inlet/outlet kit cod. 8089950.
The kit comes with a sector diaphgram,
instruction sheet and a label with the room
aeration warnings to be attached to the boi-
ler casing. The sector diaphram must be
used according to the maximum load loss
allowed by the duct, as indicated in fig. 14.
The complete range of fittings required to
carry out the installation is given in fig. 18.
The maximum length of the duct is deter-
mined by the load losses of the single atta-
ched fittings (excluding the inlet/outlet
stub pipe) and should not be greater than
8.00 mm H
O.
2
To calculate the load loss of the individual fit-
tings attached see Table 2.
2. 1 0

ELECTRICAL CONNECTION

The boiler is supplied with an electric cable.
Should this require replacement, it must be
purchased exclusively from SIME.
The electric power supply to the boiler must
be 230V~50Hz single-phase through a
fused main switch, with at least 3 mm spa-
cing between contacts.
NOTE: Device must be connected to an
efficient earthing system. SIME declines
all responsibility for injury or damage to
persons, animals or things, resulting from
the failure to provide for proper earthing
of the appliance.
Fig. 16
KEY
1 Inlet/outlet terminal
2 Sectors diaphragm
3 90° elbow MF with point
cod. 8077407
4a Extension L. 1000 (6 pz.)
cod. 8077309
4b Isolated extension L. 1000
cod. 8077306
4c Extension L. 500 (6 pz.)
cod. 8077308
5 Locking junction (5 pz.)
cod. 8092700
2. 1 0. 1 Electric switchboard
To access the electrical panel, turn off the
power supply, remove the front casing panel
and the two screws holding the control
panel to the sides (see point 4.7).
KEY
1
Air-smokes flow splitting unit
with take-off point code 8093000
2 a 90° elbow MF (6 pz.)
code 8077410
2 b Isolated 90° elbows MF
code 8077408
3 a Extension L. 1000 (6 pz.)
code 8077309
3 b Isolated extension L. 1000
code 8077306
3 c Extension L. 500 (6 pz.)
code 8077308
4
Int.-est. ring kit code 8091500
5
Intake terminal code 8089500
6
Locking junction (5 pz.)
code 8092700
7
Doubler fitting code 8091400
8
Tile with articulated joint
code 8091300
9
Roof outlet terminal L. 1390
code 8091201
10
45° elbow MF (6 pz.)
code 8077411
11
Condensation outlet L. 135
code 8092800
12
Tee condensation outlet
code 8093300
6 90° elbow MF (6 pz.) cod. 8077410
7 Extension L. 135 with point
cod. 8077304
8 45° elbow MF (6 pz.) cod. 8077411
9 Condensation outlet L. 135
cod. 8092800
10 Tile with articulated joint
cod. 8091300
11 Roof outlet terminal L. 1390
cod. 8091201
12 Tee condensation outlet
cod. 8093300
The panel will tilt forward at a sufficient angle
to allow access to the components.
To remove the protection, unscrew the fixing
screws and use a screwdriver to release the
upper tabs and free it from the control panel
(fig. 19).
Fig. 17
Fig. 18
81

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido