Ensure that the top of the facepiece seal
no hair between the facepiece's seal and the user's skin.
Failure to follow these warnings can result in serious personal injury or death.

3.10 G1 Facepiece Fit Check

Check the inhalation valve by inhaling. If sufficient flow of air is not received, do not use facepiece.
The facepiece must be repaired or replaced. Misuse can result in serious injury or death.
NOTE:
It may be necessary to exhale sharply to open the exhalation valve. If this does not release
the valve, do not use facepiece.
This device may not seal properly with your face if you have a beard, gross sideburns or similar phys-
ical characteristics (see NFPA-1500 and ANSI Z88.2). An improper face-to-facepiece seal may allow
contaminants to leak into the facepiece, reducing or eliminating respiratory protection. Do not use
this device if a proper face-to-facepiece seal can not be achieved. The face-to-facepiece seal must
be tested before each use. Never remove the facepiece except in a safe, non-hazardous nontoxic
atmosphere. Misuse can result in serious injury or death.
In order to check the facepiece-to-face tightness a leak test must be performed before each use.
WARNING
directly
contacts the user's forehead. Ensure that there is
WARNING
WARNING
(1)
Seal the inlet connector with the palm of your hand or by
attaching the regulator.
If properly aligned the bypass knob will show on the right
side of the user's facepiece.
(2)
Test tightness.
Inhale and hold breath for 10 seconds.
The facepiece must stay collapsed on face.
Exhale.
The exhalation valve should open and release the pres-
sure inside the facepiece.
(3)
If necessary retighten the straps.
If the leak test fails the facepiece must not be used.
PremAire Cadet Escape G1
Operation
US
14