Cleaning and Disinfecting

DO NOT use any cleaning substances that can or might attack any part of the SCBA.
-
DO NOT use alcohol because it may deteriorate rubber parts.
-
If not rinsed thoroughly, cleaning agent residue may irritate the wearer's skin.
-
Failure to follow these warnings can result in serious injury or death.
Depending on the cleaning policy adopted, either a designated person or the user should clean each
device after each use. ANSI standards suggest that users should be trained in the cleaning procedure.
Confidence Plus Cleaning Solution
(P/N 10009971) from MSA is recommended. It cleans and disinfects in one operation. It retains its
germicidal efficiency in hard water to inhibit the growth of bacteria. It will not deteriorate rubber, plastic,
glass, or metal parts. Refer to label for user instructions.
If the respirator is soiled (i.e. heavy smoke residue or dirt accumulation) use a sponge damp with mild
soap solution or use a soft/medium bristle brush to remove deposits that may interfere with normal
operation of:
Harness and carrier assembly
-
Cylinder and valve assembly
-
Regulator (cover outlet of the regulator to prevent water, dirt or debris from entering)
-
Inspect the entire respirator as it is reassembled. Follow the Inspection Instructions.
Preparing Solution
Follow the instructions with the Confidence Plus
If the Confidence Plus Cleaning Solution is not used, wash in a mild cleaning solution, rinse thor-
oughly, and submerge in a germicide solution for the manufacturer's recommended time.
Cleaning the Facepiece
Do not use cleaning products containing hydrocarbons or solvents [e.g. nitro-thinner].
-
Cleaned parts must not be dried in radiant heat [sun, radiators].
-
When using a drying cabinet, the temperature must not exceed 140°F (+60°C).
-
Perform a tightness test after every cleaning, disinfection and maintenance or after every
-
exchange of parts.
Failure to follow these warnings can result in serious injury or death.
In general, only the facepiece requires cleaning and disinfecting after each use.
WARNING
®
Cleaning Solution.
WARNING
PremAire Cadet Escape G1
Cleaning and Disinfecting
US
24