Specification Table; Provisions For Transformation And Installation For Other Types Of Gas; Replacing The Burner Injector; Checking Appliance Operation - Lotus PC-4G Guia Para La Intalación E Instrucciones De Us

Planos de coccion - cocinas a gas para uso profesional
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Specification table

Burner max 2,5kW - min 0,8kW
Burner injector 1/100 mm.
Minimum adjustment 1/100 mm.
Consumption
Primary air h = mm
Burner max 3,4kW - min 0,9kW
Burner injector 1/100 mm.
Minimum adjustment 1/100 mm.
Consumption
Primary air h = mm
PROVISIONS FOR TRANSFORMATION AND INSTALLATION FOR OTHER TYPES OF
GAS
All of our appliances are inspected and set up for liquid gas (see the data plate at page 2).
Any transformation or adaptation to other types of gas must be carried out only by a skilled technician. Nozzles for the various
types of gas are contained in the small bag supplied and are marked in hundredths of mm (see Specification table).
REPLACING THE BURNER INJECTOR (Fig.3)
Remove the pot-stands, the burners and the trays, and with a suitable spanner substitute the nozzles (5) with the correct ones.
Adjust the primary air flow (h) by blocking screw and the corresponding nut (7) (see the Technical Specifications Table). After
making the adjustment, replace the screw and nut, and adjust thr minimum flame by turning screw (8) to the left or right
until reaching a thermal power value of 1,2 kW for 3,5 kW burners and 1,8 kW for 5,5 kW burners.
Note: For operation with liquid gas, the minimum flame regulating screw (7) must be tightly blocked.
Important!
After transformation to another type of gas, the data plate specifications must also be changed to the type of gas for which
the appliance is now set up.

CHECKING APPLIANCE OPERATION

Instructions for use are supplied with the appliance.
Check for any gas leaks.
Check ignition and verify the burner flame is regular.
The appliance should always be used according to the instructions supplied.

MAINTENANCE

With prolonged use it is necessary to carry out regular maintenance on the appliance to ensure safe operation. To this end,
a maintenance contract is recommended. The maintenance must be carried out only by skilled technicians who are familiar
with the standards of the country where the appliance is installed, as well as the manufacturer's instructions.
GB
IE
12.8 kWh/KG
12.8 kWh/KG
G30
G31
BUTANE
PROPANE
28 mbar
37 mbar
93
93
60
60
kg/h 0,273
kg/h 0,273
20
20
117
117
70
70
kg/h 0,43
kg/h 0,43
20
20
26
9.45 kWh/m
st.
3
G20
NATURAL GAS H
20 mbar
145
adjustable
m
st./h 0,37
3
7
180
adjustable
m
st./h 0,582
3
7