Pump Dial And Button Reference - Abbott FreeGo Manual De Uso

Bomba para alimentación enteral
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PUMP DIAL AND BUTTON REFERENCE

DIAL /
BUTTON
OFF/CARGA
(OFF/CHRG)
FLUJO
(SET RATE)
FUNCTION
Primary purpose is to shut down all pump functions.
If switched from any dial position to OFF/CARGA (OFF/CHRG),
the display will briefly read "BOMB APAGANDO BOMBA" ("PUMP
SHUTDOWN"), and then enter OFF mode.
If switched from OFF/CARGA (OFF/CHRG) to any other dial
position, the pump will initiate system Self-Check Procedure. During
this procedure, user should verify that all segments on the LCD
display activate and deactivate, then the pump's software version
and serial number (for example, V1:00 AF11001000) are displayed.
Simultaneously, verify that the audio beeps at high volume, then low,
then high. If the pump has a software version later than V1:01, then
the pump will also display either NC ENABLED or DATA ENABLED, at
the end of the sequence described above. Do not use the pump if the
operation is not exactly as described above.
If external power supply is not connected, the display will be blank. If
external power supply is connected, the display will show AC/Mains
icon and battery icon.
NOTE: If external power supply is connected, pump battery will charge in any
dial setting.
Primary purpose is to set the rate/speed (the amount of fluid volume per
hour) at which feeding solution is delivered to patient.
To program feeding rate, use Up and Down Arrow Buttons. Keeping an
Arrow Button depressed will make the numerals scroll. The scrolling
rate will increase (depending on length of time Arrow Button is
depressed).
Auto Prime and Incremental Prime features are functional in this dial
position.
To set the lock-out feature, simultaneously press both Up and Down
Arrow Buttons. To deactivate lock-out feature, repeat procedure.
If lock-out feature is not set, the display will read "FIJE FLUJO" ("SET
RATE"), along with the current rate setting (from 1 to 400 mL/hr).
If lock-out feature is set, the display will read "BOMBA BLOQUEADA"
("PUMP LOCKED").
44838 Rev. J
Page 53

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido