Adding Remote Controls; Emergency Manual Release - SOMFY Elixo 500 3S io Manual De Uso

Ocultar thumbs Ver también para Elixo 500 3S io:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
EN
input causes the gate to move at reduced speed. The movement lasts as
long as the command is maintained and stops as soon as the button is
released. The system switches back to normal mode as soon as the cells
are no longer blocked.
Attention
the "wired dead man" mode requires the use of a safety contact
(e.g. keyed reversing switch ref. 1841036).
4.2.3. Operation with orange flashing light
The orange light is activated during any gate movement.
A two-second advance warning before the gate begins to move can be
programmed during installation.
4.2.4. Operation of the integrated lighting
Depending on the programming performed during installation, the lighting
comes on each time the motorisation is started and remains on when it
stops for the duration of the programmed time delay.
If a remote control is programmed for the remote lighting, operation is as
follows:
With a 2 or 4 button remote control
With a 3-button remote control
4.2.5. Operation in sequential mode with automatic re-
closing a er time delay
The gate is automatically closed a er a time-delay programmed during
installation.
A new command sent during this time-delay cancels automatic closing
and the gate remains open.
The subsequent command causes the gate to close.
4.2.6. Operation using the backup battery
If a backup battery is installed, the motorisation will work even during a
power outage.
Operation is then activated under the following conditions:
With a 9.6 V battery:
• Reduced speed.
• The additional devices (photoelectric cells, orange light, wired code
keypad, etc.) do not operate.
With a 24 V battery:
• Normal operation: speed normal, accessories functional.
Battery specifications:
• Battery life: 24 hrs; 3 operating cycles depending on the weight of
the gate.
• Recharging time: 48 hours
• Service life before replacement: Approximately 3 years.
For optimum battery life, it is recommended that the main power supply be
switched off and the motor operated using the battery for several cycles,
three times a year.
4

4.3. Adding remote controls

4.3.1. Keygo io
This operation is used to copy the function of a button on a memorised
Keygo io remote control (remote control "A") to a button on a new Keygo io
remote control (remote control "B").
A
B
Remote control "A" = "source" remote control already memorised
Remote control "B" = "target" remote control to be memorised
For example, if the button on remote control A opens the gate fully, the
button on the new remote control B will also open the gate fully.

4.4. Emergency manual release

1) Insert the key into the lock.
2) Turn the key a quarter of a turn to the le .
3) Turn the release handle to the right.
Attention
Do not forcibly push the gate. Hold the gate over its entire travel
during manual manoeuvres.
2s
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
Elixo 500 3S io

Publicidad

Tabla de contenido
loading

Tabla de contenido