POSSIBLE SETTINGS THROUGH DIP-SWITCH FIG. 4

There are 3 pair of dip-switch on the electronic card, SW1-SW2-SW3 for a total of 6 dip-switches.
To select a function put the corresponding dip-switch to position ON (upward), OFF (downward).
DIP-SWITCH SW1 TO SELECT THE TYPE OF COIN MECHANISM
SW1-1
OFF = normal functioning
ON = Free sale activated
Attention: always take SW1-1 back to position OFF, otherwise the machine remains in free sale
mode.
SW1-2
OFF = normal executive coin mechanism
ON = Coges executive coin mechanism.
DIP-SWITCH SW2 TO SELECT THE DEACTIVATION OF THE SELECTION SOLENOIDS.
SW2-1
SW2-2
OFF
OFF
100 msec delay
ON
OFF
200 msec delay
OFF
ON
300 msec delay
ON
ON
400 msec delay
DIP-SWITCH SW3 ENABLING RELAY OUTLET
The machine is equipped (as an optional ) for the installation of a relay outlet (for example for enabling a
microwave oven) which is activated after each sale according to the table below. The outlet consists of a
relay contact which closes for approximately 700 ms.
SW3-1
SW3-2
OFF
OFF
relay outlet disabled
ON
OFF
relay outlet enabled for drums 1÷4
OFF
ON
relay outlet enabled for drums 1÷8
ON
ON
relay outlet enabled for drums 1÷10
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it