Description Of Parts And Their Dimensions; Technical Data - TOPP C240 Instrucciones Para La Instalación Y El Empleo

Ocultar thumbs Ver también para C240:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.2

DESCRIPTION OF PARTS AND THEIR DIMENSIONS

Fig.2a and Fig.2b show the names of the main parts that make up the actuator.
3.3

TECHNICAL DATA

Tab 1 shows the technical data that makes up actuator C240.
MODEL
Supply voltage
Absorption
Power absorbed in load
Maximum load in thrust
Maximum load in traction
Speed of movement on empty
Duration of the max idle stroke
Protection against electric shocks
Actuator length
(1)
type of service Sz
Degree of electrical protection
Regulation of connection to window
Connection in parallel of several actuators
on the same window
Connection in parallel of several actuators
on different windows
Working temperature
Electronic limit switch on opening and ammetric absorption on closure
Weight of device including brackets
Stroke
(1)
Service of limited duration according to EN 60034
(2)
It is not possible to connect actuators from different manufacturers.When in doubt contact
Customer Service TOPP
For the actuator mounting types, see figures of par. 8
16
C240/230V
230V ~ 50Hz
8 mm/s
Classe II
1200÷4000mm
4 minutes
360mm
INSTALLATION AND USE INSTRUCTIONS
C240L/230V
230V ~ 50Hz
0,22 A
0,22 A
46 W
46 W
400 N
300 N
300 N
100 N
8 mm/s
46 s
46 s
Classe II
1200÷4000mm
4 minutes
IP 30
IP 30
(see wiring diagram)
-5°C ÷ +50°C
from 3,90 Kg (L=1200mm) to 7,00 Kg (L=2400mm)
360mm
C240/24V
24V
0,75 A
18 W
400 N
300 N
7,5 mm/s
48 s
Classe III
1200÷4000mm
1200÷4000mm
4 minutes
IP 30
No
No
(2)
Yes
360mm
EN
Tab. 1
C240L/24V
24 V
0,75 A
18 W
300 N
100 N
7,5 mm/s
48 s
Classe III
4 minutes
IP 30
360mm
C240

Publicidad

Tabla de contenido
loading