8 .DEFECTS–CAUSES-REMEDIES
Before any operation,
CAUTION !
SWITCH OFF the pump(s).
SIGNALLING
BEHAVIOUR OF THE VARIATOR
reaction
Waiting
CODE
time before
DEFECT
variator
before
stop
restart
E00
1mn
E01
1mn
≤5s
E04
≤5s
E05
≤5s
E06
E10
3s
restart
E20
3s
E23
immediate
E26
immediate
E30 E31
3s
E36
1,5s
restart
E42
5s
restart
State of the relay if the number of failure > than the allowed number of failure.
1 1
Restart of the pump after a detection of defects.
1st case - The pump has reached the maxi quantity of defects :
(from 1 to 6, according to the significance) of the same defect type
over a 24 sliding hours period. In this case, the SSM relay is activated
and the SBM relay is at rest.
The pump can be restarted by pressing on the encoder or by swit-
ching off the supply and by restoring it.
STATE OF THE RELAYS
Max qty
time
of defects
SBM
over 24
hours
rest
1mn
6
rest
1mn
6
rest
5s
2 2
6
rest
5s
2 2
6
rest
5s
2 2
6
rest
no
1
rest
5mn
6
2 2
rest
5mn
2 2
6
rest
5mn
6
2 2
rest
5mn
2 2
6
rest
no
1
rest
no
1
All incidents hereafter mentioned give rise to:
- the resting of the SBM relay (unavailable transfer)
- the activation of the SSM relay (failure transfer) when the maximum
quantity of one type of defect is reached over a 24 hours range.
- ligthening of a red LED and the defect code display.
INCIDENTS / POSSIBLES CAUSES
SSM
active
Pump is no more primed or runs
1 1
dry.
active
Load of the pump is excessive,
1 1
pump is defective, or the pump is
obstructed by particles.
active
The variator supply is
1 1
in under-voltage.
active
The variator supply is
1 1
in over-voltage.
active
A supply phase is missing.
1 1
active
The pump is locked.
1 1
active
The motor heats.
1 1
Ambient temperature higher than
+50°C.
active
The variator or the motor is
1 1
in short-circuit.
active
The thermal sensor of the motor is
1 1
defective or has a wrong connec-
tion.
active
The variator heats.
1 1
Ambient temperature higher than
+50°C.
active
Internal problem of converter
1 1
active
The cable of the sensor (4-20mA)
1 1
is cut (Mode 2).
2nd case - The pump hasn't reached the maxi quantity of defects :
In this case, the SSM and SBM relays are at rest. Only a switch off
and a restoration of the supply allows the restart.
- For both cases, it is necessary to proceed at first to the deletion of
the defect. In case of intervention on the pump, swith off the supply
beforehand.
If the defect is major, the action of an after-sales technician is required.
28
REPAIRING
Prime the pump once again by filling it (see
chapter 6-3).
Check the tightness of the foot valve.
Density and/or viscosity of the conveyed fluid
are too big.
Dismantle the pump and replace the defecti-
ve components or clean them.
Check voltage at the variator terminals.
Mini 380V -6%.
Check voltage at the variator terminals.
Maxi 440V +6%.
Check the supply.
Dismantle the pump, clean it and replace the
defective parts. It may be a mechanical failure
of the motor (bearings).
Clean the cooling ribs of the motor.
The motor is foreseen to run at an ambient
temperature of +50°C.
Dismantle the motor-variator of the pump,
check it or replace it.
Dismantle the motor-variator of the pump,
check it or replace it.
Clean the cooling ribs rearside and under the
variator as well as the fan cover.
The variator is foreseen to run at a maximum
ambient temperature of +50°C.
Call on after-sales technician.
Check the correct supply and the cable
connection of the sensor.
If the failure is suppressed.