7. Again, check that the unit is firmly mounted by applying slight pressure to the left and the right-hand
sides of the unit.
If refrigerant piping is already embedded in the wall, do the following:
1. Hook the top of the indoor unit on the upper hook of the mounting plate.
2. Use a bracket or wedge to prop up the unit, giving you enough room to connect the refrigerant piping,
signal cable, and drain hose. Refer to next picture for an example:
3. Connect drain hose and refrigerant piping (refer to Refrigerant Piping Connection section of this manual for
instructions).
4. Keep pipe connection point exposed to perform the leak test (refer to Electrical Checks and Leak Checks section of
this manual).
5. After the leak test, wrap the connection point with insulation tape.
6. Remove the bracket or wedge that is propping up the unit.
7. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the
hooks along the bottom of the mounting plate.

OUTDOOR UNIT INSTALLATION

55