2.0 - TECHNICAL DATA
• Use
• Ambient temperature
• Supply voltages (see table 2)
• Supply voltage tolerance
• Electric wiring
• No. cycles/hour**
DN 32 - DN 40 - DN 50 - DN 65 - DN 80 - DN 100
• Absorbed power
• Maximum operating pressure
• Opening time
• Closing time
• Protection rating
• Class
• Mechanical resistance
• Rp Threaded connections
• Flanged connections to be coupled with PN 16 flanges : (DN 32 - DN 40 - DN 50 - DN 65 - DN 80 - DN 100 - DN 125 - DN 150)
• NPT threaded or ANSI 150 flanged connections : on request
• Filter element
• In compliance with
* Only single-phase, the device does not work if powered with three-phase voltage.
** For cycles/hours with ON/OFF times different from those indicated, contact our technical office
2.1 - MODEL IDENTIFICATION
EVP/NC : Fast opening
EVPF/NC : Fast opening + flow adjustment
2.2 - SIL LEVEL
The SIL level of the stand-alone solenoid valve is SIL 2; when two solenoids are installed in series and the relative leak test
(Valve Proving System), certified according to EN 1643, the achieved level is SIL 3, as set forth in EN 676:2008. The solenoid
valve has PL d level. For further data refer to the SIL LEVEL table (table 3).
3.0 - COMMISSIONING THE DEVICE
3.1 - OPERATIONS PRIOR TO INSTALLATION
• It is necessary to close the gas upstream of the valve prior to installation;
• Make sure that the line pressure DOES NOT EXCEED the maximum pressure declared on the product label;
• Any protective caps (if any) must be removed prior to installation;
• Valve pipes and insides must be clear of any foreign bodies;
If the device is threaded:
• make sure that the pipe thread is not too long, to prevent damaging the body of the device when screwing it on;
EVP/NC - EVPF/NC
: non-aggressive gases of the three families (dry gases)
: -20 ÷ +60 °C
: 24 Vdc - 24 V/50 Hz - 110 V/50-60 Hz - 230 V/50-60 Hz*
: -15% ... +10%
: cable gland PG 11
:
195 (ON time 5s - OFF time 13.5s)
~
DN 125 - DN 150
90 (ON time 10s - OFF time 30s)
~
: see table 2
: 360 mbar
: <1 s
: < 1 s
: IP65
: A
: Group 2
: (DN 32 - DN 40 - DN 50) according to EN 10226
ISO 7005 / EN 1092-1
: 1 mm wire mesh on threaded and flanged connections DN 32 - DN 40 - DN 50
filtering
filtering
: Regulation (EU) 2016/426 (Appliances burning gaseous fuels)
Directive EMC 2014/30/EU - Directive LVD 2014/35/EU
Directive RoHS II 2011/65/EU
50µm on DN 65 - DN 80 - DN 100
10µm on DN 125 - DN 150
14
Madas Technical Manual - REV. 0 of 10
May 2018
th