Venting Outside Through the Roof
1. Measure and mark the lines as the cutout chart shown. Use
a saber saw or keyhole saw to cut an opening through the top
of the cabinet and the roof for the vent.
Cutout chart
Cabinet Height
Hole Shape and Size
12" (30.5 cm)
A 8
" wide x 6¼" deep (21 cm x 15.9
17
64
cm) rectangular opening in the cabinet top
is required for damper transition clearance.
A
A. Cutout
B. 8
" (21cm) x 6¼" (15.9 cm)
17
64
Cabinet Height
Hole Shape and Size
15" (38.1 cm)
A 6¼" (15.9 cm) diameter round opening is
required.
A
A. Cutout
B. Ø 6¼" (15.9 cm)
2.
Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A. Vent transition
B. 3.5 x 9.5 mm screw
C
B*
D
C. 7¾" (19.7 cm) centerline to cabinet front
D. Centerline
B*
C
D
C. 7
" (19 cm) centerline to cabinet front
1
2
D. Centerline
A
B
Venting Outside Through the Wall
1. Measure from the bottom of the range hood liner to the
horizontal centerline of the vent opening (A)
B
A
2. Remove the vent duct from the range hood liner.
Transfer measurement A to the cabinet back wall. Measure
from the underside of the cabinet.
3. Mark the cutout as shown. Use a saber saw or keyhole saw to
cut a round opening through the top of the cabinet and the
exterior wall for the vent.
C
A
B
Non-Vented (recirculating) Installation through the
Cabinet / Soffit
Recirculating through
the cabinet top wall
A
G
B
D
F
E
H
A. Ceiling
B. Recirculating grid
C. Soffit
D. 6" round vent system
E. Range hood
6
C
A. Measurement A
B. Horizontal centerline of vent opening
C. Range hood liner
A. Measurement A
B. Centerline
C. 6¼" (15.9 cm) round
cutout
I
F. Cabinet
G.Wall
H. 12" (30.5 cm) min. cabinet height
I. 17" (43.2 cm) min. vent cover height