DIP1. OPEN command switching
DIP2. Selection of movement direc-
tion. The opening direction is determi-
ned by looking at the device from the
inspection side.
DIP3. Electric lock release
DIP4. Pre-flashing light
2.
SELECTION
A Door type Magnum, door with OVER30H
B Refrigerator door with OVER30H
C Door with nr. 2 OVER30H
D Refrigerator door with OVER30H that is closed by pushing it with force
E Door with OVER60H
F Refrigerator door with OVER60H
G Refrigerator door OVER60H that is closed by pushing it with force
H Fire stop door with OVER30H (*)
Fire stop door with OVER60H (*)
I
(*)
For further information, please see Chapter 3 in the OVER installation manual.
3.
WARNING
LED
POWER ALARM
SA
4.
CONTROL PANEL INSTALLATION AND STARTING
4.1
Firmly secure the electric board.
4.2
Drill a hole on the underside of the electric cabinet for cable routing. If cables are accessible, secure by means of appropri-
ate cable fittings (not provided).
4.3
Keep power leads at least 8 mm from control and motor leads at terminal strip connections (eventually using clamps). Warn-
ing: to ensure proper operation of the unit and adequate resistance to disturbances, place the motor cable and the encoder
cable in separate raceways. Furthermore, the distance from the electric board to the geared motor must not be more than
5 m. Should this distance be greater owing to special installation requirements, install the geared motor and the electric
board on the same side inverting the switch-on sequence of the carriages and the transmission. In this case the operation
of the DIP2 changes (OFF = opening to the left - ON = opening to the right). If it is not possible to install the geared motor
and the electric board on the same side, connect some external buttons (not supplied by us) in the appropriate position.
Warning: the operations regarding point 4.5 are without safety devices. The trimmer can only be adjusted with door not mov-
ing.
4.4
Set the S1-S2-S3 selections according to the chosen application. Set TC and RF to maximum and VM to minimum. Make
a jumper between safety devices (1-6, 1-7, 1-8 and 1-42) and stop (1-9). Select desired direction of movement.
4.5
Power (from batteries and mains) and check that door operates properly by sending several open, close and step-by-step
commands. Set VM and check opening and closing speed. Attention: Upon each turning on the electric board automatically
resets so as to permit the first opening and closing to be made at low speed in order to learn the end-of-travel positions
(acquisition phase).
4.6
Adjust with RF the motor force and the obstacle detection.
4.7
Remove jumpers, connect safety devices (1-6, 1-7, 1-8 and 1-42) and stop (1-9), and check for proper operation.
4.8
If desired, adjust automatic closing by means of TC (enabled by 1-2).
4.9
Connect any accessories and check their function.
DITEC S.P.A - IP1552 - LOGICHE
Right opening for one wing doors and
working for two-wing door.
- With MOTH unlocking piston
- With KZ17OV lock without release
Fixed at 3 s: disabled during opening,
and enabled only during automatic
closing with TC set to more than 3
seconds.
APPLICATION TYPE
Power ON
This indicates that at least one of the 1-6,
1-7, 1-8, 1-9 or 1-42 contacts is open
OFF
1-5
Left opening for one wing door.
- With KZ17OV type lock with release
Fixed at 3 s: enabled both during ope-
ning and closing.
S1
N.C.
N.C.
N.O.
N.O.
N.C.
N.O.
ON
Encoder / Accessories output (0-1) fai-
lure
12
ON
1-3
S2
S3
N.C.
N.C.
N.O.
N.O.
N.C.
N.C.
N.C.
N.O.
N.O.
N.C.
N.O.
N.C.
FLASHING
/