Electrical Connection - DITEC LOGIC HE Manual De Instalación Cuadro Eléctrico

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
1.

ELECTRICAL CONNECTION

GB
1.1 Controls
Control
1
2
N.O.
1
3
N.O.
1
4
N.O.
1
5
N.O.
1
6
N.C.
1
7
N.C.
1
8
N.C.
1
9
N.C.
1
20
N.O.
1
42
N.C.
OPEN
SAFETY
PARTIAL MANUAL OPENING
WARNING: Link up all N.C. contacts (if not used) by means of jumpers. The terminal bearing the same number are equivalent. The
given operating and performance features can only be guaranteed with the use of DITEC accessories and safety devices.
DITEC S.P.A - IP1552 - LOGICHE
Function
AUTOMATIC CLOSING
OPENING
CLOSING
STEP BY STEP
OPENING SAFETY CONTACT It stops the opening operation.
CLOSING SAFETY CONTACT It stops the closing operation.
REVERSAL SAFETY CON-
TACT
STOP / HOLD TO RUN
EMERGENCY STOP
PARTIAL OPENING
EMERGENCY CLOSING
STEP BY STEP / OPEN
REVERSAL SAFETY CON-
TACT
The automatic closing function is enabled by a permanent contact. The
timer counter, set by TC, starts at the end of opening manoeuvre. Expired
the time, the closing operation takes place.
It starts the opening operation.
It starts the closing operation.
It starts the closing or opening operation in sequence: open-stop-clo-
se-open. Warning: if the automatic closure is enabled, the stop is not
permanent but lasts for the time set by means of TC.
Reverses movement (re-opens) during closing.
When door is not moving, inhibits all operation.
It stops any movement. If contact remains open, service man fun-
ction is
enabled. Under these conditions, triggering of any of the
safety devices causes door to immediately stop moving. Step-by-step
and automatic closing controls are disabled. When 1-9 contact is reset,
the door stays stopped until the next open or close command is given.
In order to obtain a total stop after the opening 1-9 (for instance the
emergency stop), connect the opening commands to terminals 9-3, 9-20
and the closing commands to terminals 9-4.
It causes a partial opening of 1 m.
This triggers the closure of the fire-stop door due to the action of the
counterweights even when not powered. Command 1-42 prevails over
any other command or safety device and activates the closure of the
door even if the control panel breaks down.
This is the seat for the coupling of the radio receiver.
The remote control function is select by means of DIP1 (OFF = 1-5; ON
= 1-3).
Has the same function as contact 1-8. To fit the safety card (photocell or
detection loop), remove the J11 jumper.
Partial opening (except selections 2 [H] and [I]) is set off by manual
opening of the door by at least 30 mm. During this manoeuvre the pre-
flashing light and electric lock release (DIP3=ON) are disabled.
10
Description

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Logic hef

Tabla de contenido