Electrical Wiring - Sime MURELLE 25 OF ErP Manual De Instrucciones

Ocultar thumbs Ver también para MURELLE 25 OF ErP:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9. .Visualizzazione.corrente.al
.....modulatore.in.mA
and. deposits,. the. use. of. inhibitors. such. as.
Sentinel  X100  or  Fernox  Protector  F1. is.
10. .Visualizzazione.ore.di.funzionamento.del.bruciatore.in.h.x.100.(es..14.000.e.10)
recommended.after.cleaning.the.system..
It. is. important. to. check. the. concentration.
of.the.inhibitor.after.each.system.modifica-
tion. and. during. maintenance. following. the.
manufacturer's. instructions. (specific. tests.
are.available.at.your.dealer)..
The.safety.valve.drain.must.be.connected.to.
a.collection.funnel.to.collect.any.discharge.
during.interventions..
11. .Visualizzazione.numero.di.accensioni.del.bruciatore.x.1.000.(es..97.000.e.500)
If. the. heating. system. is. on. a. higher. floor.
than. the. boiler,. install. the. on/off. taps. sup-
plied. in. kit. optional. on. the. heating. system.
delivery/return.pipes..
WARNING: Failure to clean the heat system 
or  add  an  adequate  inhibitor  invalidates 
the device's warranty.
12. .Visualizzazione.codice.errore
.......ultima.anomalia
Gas.connections.must.be.made.in.accordan-
ce. with. current. standards. and. regulations..
When. dimensioning. gas. pipes. from. the.
meter.to.the.module,.both.capacity.volume.
(consumption).in.m
3
/h.and.gas.density.must.
be.taken.into.account..
The. sections. of. the. piping. making. up. the.
13...Visualizzazione.codice.errore
system.must.be.such.as.to.guarantee.a.sup-
.......penultima.anomalia
ply. of. gas. sufficient. to. cover. the. maximum.
demand,.limiting.pressure.loss.between.the.
gas.meter.and.any.apparatus.being.used.to.
not.greater.than:
–. 1.0.mbar.for.family.II.gases.(natural.gas);
–. 2.0. mbar. for. family. III. gases. (butane. or.
propane).
14...Visualizzazione.numero.totale
.......delle.anomalie
An.adhesive.data.plate.is.sticked.inside.the.
front.panel;.it.contains.all.the.technical.data.
identifying.the.boiler.and.the.type.of.gas.for.
which.the.boiler.is.arranged.
2.3.1 
Filter on the gas pipe
15. .Contatore.accessi.parametri
The.gas.valve.is.supplied.ex.factory.with.an.
.......installatore.(es..140.accessi)
inlet.filter,.which,.however,.is.not.adequate.
to.entrap.all.the.impurities.in.the.gas.or.in.
gas.main.pipes..
To.prevent.malfunctioning.of.the.valve,.or.in.
certain.cases.even.to.cut.out.the.safety.devi-
ce.with.which.the.valve.is.equipped,.install.
16.  Contatore.accessi.parametri
.......OEM.(es..48.accessi)
an.adequate.filter.on.the.gas.pipe.
2.5 
SYSTEM FILLING (fig. 4)
Filling.of.the.boiler.and.the.system.is.done.
by.the.system.filling.(11)..
The.charge.pressure,.with.the.system.cold,.
must.be.between.1 and 1.5 bar..
During.system.filling.you.are.recommended.
to.keep.the.main.switch.turned.OFF..
Filling. must. be. done. slowly. so. as. to. allow.
any. air. bubbles. to. be. bled. off. through. the.
air.valves..
Should. the. pressure. have. risen. well. above.
the.limit.expected,.discharge.the.over.pres-
sure.by.opening.the.pressure-relief.valve.
2.5.1 
Emptying the system (fig. 4)
Use. the. drain. tap. to. empty. the. system. (7)..
Turn.off.the.boiler.before.doing.this.
2.6 
FLUES/CHIMNEYS
A.chimney.or.flue.for.the.evacuation.of.the.
combustion. products. into. the. atmosphere.
must. correspond. to. the. requisites. prescri-
bed.by.the.laws.in.force..
2.11 
ELECTRICAL WIRING
If.you.must.replace.the.electric.power.cable.
supplied.with.the.boiler,.order.it.exclusively.
from.Sime..
The. power. supply. must. be. single-phase.
230V. -. 50. Hz. through. a. main. switch. pro-
tected.by.a.fuse.with.a.distance.of.at.least.3.
mm.between.contacts.
The boiler must be connected with an effi-
cient grounding system. SIME shall not be 
held  liable  for  injury  or  damage  resulting 
from failure to ground the boiler. 
ATTENTION:  Before  every  intervention  on 
the boiler, cut off the electricity supply by 
means  of  the  main  switch  of  the  system, 
since even if the boiler is "OFF", the elec-
trical panel remains connected to the elec-
tricity.
2.11.1  Chronothermostat connection
Connect. the. chronothermostat. as. indica-
ted. in. the. boiler. electrical. diagram. (see 
paragraph  2.12). after. having. removed. the.
existing.bridge..
The. chronothermostat. to. be. used. must. be.
of. a. class. conforming. to. the. standard. EN.
607301.(clean.electrical.contact).
2.11.2  Remote control SIME HOME
connection (optional)
The. boiler. is. designed. for. connection. to. a.
remote. control. unit. SIME.HOME,. supplied.
on.request.(code.8092280/81).
The.remote.control.unit.SIME.HOME.allows.
for.complete.remote.control.of.the.boiler..
The. boiler. display. will. show. the. following.
message:
For.installation.and.use.of.the.remote.con-
trol,.follow.the.instructions.in.the.package.
NOTE: Ensure PAR 10 set to 1 (PAR 10 = 1).
2.11.3  External  sensor connection
The.boiler.is.designed.for.connection.to.an.
external. temperature. sensor,. supplied. on.
request. (code. 8094101),. which. can. auto-
matically.regulate.the.temperature.value.of.
the. boiler. output. according. to. the. external.
temperature.. For. installation,. follow. the.
instruction.in.the.package..
ES
PT
ENG
69