Specifications; Troubleshooting - Allmand NIGHT-LITE GR Serie Manual Del Operario

Cadena
Ocultar thumbs Ver también para NIGHT-LITE GR Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Models and Serial Numbers
Model and serial number information is required for
product support and repair parts. Following are the model
and serial number locations of the primary components.
Trailer
The serial number tag for the light tower trailer is located
on the left side of the trailer tongue (A, Figure 23).
23

Specifications

Overall Dimensions
Dimension
Length - Towing Transport
Width - Towing Transport
Width - Outriggers Deployed
Height - Towing Transport
Height - Tower Fully Elevated
Shipping Weight
Gross Vehicle Weight Rating
(GVWR)
Trailer
Specification
Gross Axle Weight Rating
(GAWR)
Tire Size and Rating
Rims
Cold Tire Inflation Pressure
Max On-Road Speed
Max Off-Road Speed
Frame Structure
Axle
Hubs
Springs
Available Hitches
Trailer Road Lighting
Trailer Road Lighting Connector
A
Imperial
Metric
9 ft - 6 in
2,90 m
4 ft - 0.25 in
1,23 m
7 ft - 10 in
2,39 m
8 ft - 2 in
2,49 m
23 ft - 0 in
7,01 m
835 lbs
379 kg
1200 lbs
544 kg
Imperial
Metric
2200 lbs
998 kg
ST175/80R13 Load Range 'C'
13 x 4.5 JJ with 0.0 inch offset
36 psi
248 kPa
65 mph
105 km/h
20 mph
32 km/h
Formed welded steel design
Tubular design with 1.5 - 2.0 inch
(38,1 -50,8 mm) camber
(5) 1/2-20 UNF studs on a 4.5 inch
(114,3 mm) bolt circle
Elliptical springs - 3 leaf
2 inch (50.8 mm) ball coupler
Stop, turn, tail, side markers,
illuminated license plate bracket
4-way flat connector
Trailer
Lifting Eye - Rated Capacity
Forklift Pockets / Tie-Down
Points
Outrigger and Stabilization
System
Maximum Wind Speed - Tower
Elevated and Outriggers and
Stabilizers Deployed
Light Tower
Structure
Actuation
Guide Pads
Power Cable
Tower Rotation
Tower Rotation
Light Fixtures
LED
Color Temperature
Power Consumption - per Fixture 250 W
Lumens - per Fixture
Electrical
Frequency
Volts
Amps
Available Outlets

Troubleshooting

DANGER
Electrocution Hazard
High voltage is present when unit is connected to
external power source. Disconnect unit from external
power source before doing any troubleshooting.
Contact with wires made bare by damaged, cut or
worn insulation could result in death or serious injury.
Replace damaged wiring before operating unit.
Before trying to do any troubleshooting, read Safety.
1500 lbs
680 kg
2 each side
Left and right side outriggers with
adjustable screw type jacks, 1
adjustable screw type tongue jack
50 MPH
80 km/h
Four-section tubular steel design
Standard - Manual winch
Polyethylene self-lubricating
Coiled cable secured at top of
sections to minimize possibility of
tangling
Complete tower rotates 345°
Complete tower rotates 345°
5000K
38,081
60 Hz / 50 Hz
60 Hz - 120 / 50 Hz - 220
60 Hz - 16.7 / 50 Hz - 15
20A 120V duplex GFCI outlet (NEMA
5-20R)
15A 220V IEC 60309 outlet (6H)
en
English
21

Publicidad

Tabla de contenido
loading

Tabla de contenido