optimal pressure conditions, in the indoor smoker, the pressure inside
the unit is electronically controlled, and little to no steam will be
released in normal working conditions.
Error messages
In some rare instances you could get error messages displayed on
the indoor smoker's control panel. See below for the error description
and solutions when appearing.
E1: means open circuit. There is a sensor in the base of the cooker,
connected by the insert pins at the bottom of the removable
cooking pot. If E1 appears, it is very likely that the connection pins
underneath the cooking pot are not well seated in the socket.
Unplug from wall outlet
Check the insert pins and the socket for damage
Straighten the pins if deformed.
Try to turn the cooking pot slightly to the left and to the right to
make sure the pins are properly seated in the socket.
Make sure no condensation water stays in the housing cavity or in
the socket that could cause a short circuit. Make sure the
housing's cavity is dry. If the socket was ever immersed in water,
discontinue use and contact Customer service.
E2: means short-circuit of the sensor or unit overheat. In case of
overheat the unit is likely to display E3 (see below) then E2. This can
happen in some cases when the unit is heating without any water in
the cooking pot. If the case:
Add a little bit of water in the cooking pot
Let the unit cool down. The function should then be restored.
E2 might also appear when some foreign substance, food or liquids
are entering the socket at the center of the base, which creates a
short circuit. In this case, discontinue the use and contact Customer
service for maintenance/repair.
E3: Means "Overheating". When this happens:
Add a little bit of water in the cooking pot
Let the unit cool down. The function should then be restored.
If this E3 error message appears again on a regular basis, then it is
likely that the cooking pot or the heating plate inside the base
Copies of the I/B. Please reproduce them without any
changes
except
under
International USA. The pages must be reproduced and folded
in order to obtain a booklet A5 (+/- 148.5 mm width x 210 mm
height). When folding, make sure you keep the good
numbering when you turn the pages of the I/B. Don't change
the page numbering. Keep the language integrity.
what is inside the frame.
20
Assembly page 20/64
special
instruction
from
Print only
EPCK 40911 - 160822
Team