Troubleshooting/Maintenance
Condition
Over-
Temperature
No AC
Output
Resetting
the Inverter
18-11-135-9338A1.indb 21
Explanation
The thermal resistor
exceeds 176° F (80° C).
There is no AC output for
most critical conditions.
The ground fault circuit
will also interrupt AC
power when too much
current flows on the
ground connector of the
GFCI.
21
Solution
Allow the inverter to cool.
Do not block the cooling
slots or airflow over and
through the inverter.
Reduce the load on the
inverter to the continuous
rated output.
Follow instructions of
above event conditions
to restore output power.
If GFCI is tripped, remove
load and push in the
reset switch of the GFCI
receptacle to restore AC
output.
To reset after shutdown
occurs, switch the
inverter's ON/OFF/
REMOTE switch to the
OFF (O) position. Check
the source of the problem
and correct. Switch the
inverter's ON/OFF switch
to the ON (I) or REMOTE
(II) position.
12/6/2018 3:02:49 PM