2.3.2. Modifying the drive rotation direction
1) Press the S button to reverse the rotation direction.
Green LED ON = Open/CCW, Green LED blinking = Open/CW
2) Press the M button to confirm the change and go to the next step. The red light is on.
2.3.3. Back release setting
Move the curtain to the OPEN (UP) end limit
1) Press the S button in sequencing mode to adjust the back release position.
2) Press the M button to confirm the new back release position.
The LED flashes alternatively from green to red and the curtain starts to open and close.
2.3.4. SILENT or HI-SPEED mode
On the motor you can switch from the silent mode to the Hi-speed mode by sliding the "selector" from SILENT to
Hi-SPEED. In silent mode, the motor speed is 7.5cm/s. And in hi speed mode, the speed can be adjustable, refer 2.3.5
for details.
2.3.5. Speed setting
1) Press the S button to switch the speed from 12.5 cm/s - 15 cm/s (default speed) - 17.5 cm/s - 20
cm/s and back to 12,5 cm/S
2) Press the M button to confirm and go back to direction setting.The green LED is on or blinking.

2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION

2.4.1. Questions about the Glydea Ultra?
Observations
The motorised product does
not operate.
2.4.2. Erasing the memory of the motor (Fig G)
Press the S button until the motorised product moves 3 times.
All the settings are erased.

3. USE AND MAINTENANCE

This drive is maintenance-free
3.1. OPEN AND CLOSE BUTTONS
Pressing the Open or Close button fully opens or closes the motorised product.
3.2. STOP FUNCTION
The motorised product is moving.
Briefly press Stop: the motorised product stops automatically.

3.3. TIPS AND RECOMMENDATIONS FOR USE

3.3.1. Questions about the Glydea Ultra?
Observations
The motorised product
does not operate.
If the motorised product still does not work, contact a motorisation and home automation professional.

4. TECHNICAL DATA

Power supply
Operating temperature
Index protection rating
Safety level
Copyright © 2017 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved
Possible causes
The wiring is incorrect.
The control point is not
compatible.
(Fig H)
(Fig I)
Possible causes
The motorisation is in thermal protection mode.
Solutions
Check and reconnect the power supply
Check for compatibility and replace the
control point if necessary.
Solutions
Wait for the motor to cool down.
100V - 240V
0°C to + 60°C
IP 30
Class I
.