9. Tips and recommendations

9.1 Problem with the Oximo 40 WireFree™ RTS?
Problems
The roller shutter is not operational.
The roller shutter stops briefly
before raising, when the Up button
is pressed.
The roller shutter performs two brief
movements in the same direction,
when the Down button or STOP/my
button is pressed.
The roller shutter remains in initial
position when the STOP/my button
is pressed.
The roller shutter moves briefly and
stops.
The roller shutter stops too soon.
It is impossible to set the second
end limit.

9.2 Replacing a lost or broken RTS control point or RTS sensor

9.3 Restoring the original configuration

9.4 Recharging / Replacing the battery

9.5 Replacing / Adding a solar panel

Copyright © 2009 Somfy SAS. All rights reserved.
Possible causes
The wiring is incorrect.
The motor is deactivated.
The battery is weak.
The control point battery is weak.
The control point is not compatible.
The control point used has not been
programmed into the motor.
External radio equipment is interfering
with the radio reception (e.g. Hi-Fi
radio headphones).
The battery is weak.
The battery is weak.
The favourite position is not active.
The favourite position has been
deleted.
The crown is incorrectly positioned.
The roller shutter is locked by the anti-
freeze function.
The end limits have been incorrectly
set.
The roller shutter has detected an
obstacle.
The distance between the two end
limits is too small.
See manual for Oximo WireFree™ Battery.
See manual for Oximo WireFree™ Battery.
See manual for Oximo WireFree™ Battery.
See manual for Oximo WireFree™ Solar Panel.
Oximo 40 WireFree™ RTS
Solutions
Check the wiring and modify it if
necessary.
Activate the motor using the battery's
PROG button.
See manual for Oximo WireFree™
Battery.
Check whether the battery is weak
and replace it if necessary.
Check for compatibility and replace
the control point if necessary.
Use a programmed control point or
program the control point, see section
8.2.
Turn off all radio equipment nearby.
See manual for Oximo WireFree™
Battery.
See manual for Oximo WireFree™
Battery.
Activate the favourite position, see
section 6.5.
Program a favourite position, see
section 8.1.
Fit the crown correctly.
Wait for the temperature to rise.
Readjust the end limits, see section
8.4.
If the obstacle is visible, remove it.
If the obstacle is invisible, check the
roller shutter assembly.
Increase the size of the roller shutter.