Maintenance and troubleshooting

After maintenance and troubleshooting

6.3 Fault table

Fault description
High noise generation/
knocking noises
Restricted lifting speed
Lifting column does not
retract or extend evenly
Lifting column does not
retract or extend
Lifting columns have diffe-
rent extension heights
during synchronous opera-
tion
6.4 After maintenance and troubleshooting
110
Cause
Overload of the lifting
column, crooked spindle
deflects.
Motor faulty.
Too much play between the
profiles due to wear on the
plastic sliding elements (as a
result of soiling or use of
chlorine cleaner).
Motor, limit switch or inner
wiring faulty.
Electrical faults.
Perform the following steps once maintenance and troubleshooting
are complete:
1.
Check that all screw connections loosened previously are
secure.
2.
Ensure that all tools, materials and other equipment used
have been removed from the work area.
3.
Clean the work area and remove any escaped substances
such as liquids, processing material or similar products.
Lifting column Multilift I/Multilift II
Remedy
Contact RK Rose
+Krieger GmbH.
Contact RK Rose
+Krieger GmbH.
Contact RK Rose
+Krieger GmbH.
Contact RK Rose
+Krieger GmbH.
Carry out an initialisation run.
Ä Instructions for the con-
troller
Personnel
Assembly staff
Assembly staff
Assembly staff
Qualified elect-
rician
Assembly staff
20.02.2019