Spacing
Bearing connection
Fastening
20.02.2019
Fig. 26: Spacing
5.
The greater the distance between lifting columns,
the better the moving performance. Control devi-
ations in synchronous operation have a more
severe effect if the lifting columns are positioned
close to one another.
Make sure that the lifting columns are positioned as far apart
as possible.
Fig. 27: Bearing connection
6.
If the lifting columns are not positioned exactly
parallel, the upper distance between the lifting
columns can change.
Therefore, only one lifting column must be
secured to the connecting construction (fixed
bearing). All other lifting columns must be
mounted with a floating bearing.
Make sure that the bearing connection matches the require-
ments and use of the connecting construction.
7.
Observe the following:
Countersunk screws for fastening the connecting construc-
tion are centred when they are tightened in the drilled holes.
If the drilling pattern on the connecting construction does not
match that on the lifting column, this will cause distortions or
destroy the drilled holes.