RK Rose+Krieger Multilift I Manual De Montaje página 114

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Technical data
Technical data - Multilift I
Electrical connection
Current consumption, max. [A]
Power input, max. [W]
Duty cycle (DC) with nominal
load
Service life
Protection
rating
without milled slot
with milled slot
Continuous sound pressure
level [dBA]
Lifting speed [mm/s]
Compressive force/tensile
force, max. [N]
Compressive force/tensile
force, max. [N]
(in medical applications)
Position signal
(Pulses per mm of travel dis-
tance)
Number of hall sensor chan-
nels
Operating conditions
114
Mono
2-pin DIN LS plug connector
DC 10% at 20 minutes:
n
2 minutes movement
n
18 minutes standby
n
10 000 double strokes with stroke 500 mm, 1000 N, 16 mm/s
5 000 double strokes with stroke 500 mm, 3000 N, 8 mm/s
n
(If supporting surface and contact surface is covered over the entire
surface and free from drilled holes, or if using the SnycFlex adapter
plate)
8
3000/1000*
1000/1000*
Ä "Max. compressive/tensile force depending on the stroke length"
on page 116
2000/500*
1000/500*
Ä "Max. compressive/tensile force depending on the stroke length in
medical applications" on page 117
0
Temperatures (in dry rooms): +5°C - +40°C
n
Relative air humidity: 30% - 75% (no condensation)
n
Air pressure: 700 hPa - 1060 hPa (up to 3000 m altitude)
n
* Only in conjunction with additional bottom assembly plate
installed by RK Rose+Krieger GmbH. The tensile force load type
must already be taken into account and cannot be retrofitted by
the operator.
Lifting column Multilift I/Multilift II
8-pin DIN plug connector
n
n
8-pin Mini-Fit Jr. plug con-
nector
4.5
120
IP 20
IP 10
< 60
16
8
3000/1000*
2000/500*
2
1
Synchro
16
1000/1000*
1000/500*
1
1
20.02.2019

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Multilift ii

Tabla de contenido