5.4.2 Assembling the external profile - Multilift I
Positioning the lifting column
Fastening the lifting column
Fig. 29: Connection points
20.02.2019
Installing the lifting column at the interfaces > Assembling the external profile - Multilift I
Personal:
Schutzausrüstung:
Prerequisite:
n
The substrate (e.g. metal plate screwing surface or foot) has
been prepared for fastening the lifting column.
1.
Place the external profile of the lifting column on the sub-
strate, and position it.
2.
Insert 4 screws into the drilled holes (Fig. 29/1) on the sub-
strate and lifting column.
3.
Tighten the screws alternating between them diagonally.
Screw size
- Multilift I
M8
ð The Multilift I lifting column has been fitted to the sub-
Lifting column Multilift I/Multilift II
RK Rose+Krieger GmbH recommends that the lifting
column be fastened to the supporting/contact surface
on the motor side.
n
Assembly staff
n
Protective clothing
n
Protective gloves
n
Safety shoes
The supporting surface of the lifting column must
rest fully on a metal plate of at least 5 mm in
thickness.
Strength
8.8
The minimum screw depth for initial installation is
20 mm, and 40 mm for repeated installation.
Use all the connection points of the Multilift for
the connecting constructions and options mod-
ules.
strate.
Assembly
Tightening torque [Nm]
15
105