5.2 Conditions at the installation site
5.3 Assembling the linear unit on the substrate
5.3.1 Assembling the linear unit with clamping bars
Applicable to
Inserting clamping bars
Fig. 12: Inserting clamping bars
26.03.2019
Assembling the linear unit on the substrate > Assembling the linear unit with clamping bars
The following conditions must be met at the linear unit's installation
site:
n
The substrate and the mounting surfaces are designed for
static and dynamic loads.
The installation site has a smooth ground surface, is free from
n
vibrations, oscillations or shocks, and is moisture-resistant.
n
Sufficient lighting is available.
n
The installation site is clean and dry, and free from dust and
objects.
n
The atmosphere must be free from solvents.
n
All of the connections required on site are available.
Room temperature: 0 - 60°C
n
Relative humidity: 0 - 85%
n
n
Temperatures below the dew point are not permitted.
Version
Size
Personal:
Schutzausrüstung:
Prerequisite:
n
The substrate must be prepared for the linear unit being fixed
to it.
1.
Insert clamping bars (Fig. 12/1) into the slot of the guide pro-
file.
Linear unit RK MonoLine R/RK MonoLine Z
RK MonoLine R, Z
40/60/80/120
n
Assembly staff
Protective clothing
n
n
Protective gloves
n
Safety shoes
Depending on the length of the linear unit, 2 or
more clamping bars must be inserted on each
side of the guide profile (Fig. 12/2).
Assembly
93