4.
Run home power supply cable through strain relief, into
terminal box
.
A
C
D
E
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
5.
Use UL listed wire connectors and connect black wires (C)
together.
6.
Use UL listed wire connectors and connect white wires (E)
together.
WARNING: Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in
terminal box. Failure to do so can result in death or electrical
shock.
7.
Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8.
Tighten strain relief screw.
9.
Install terminal box cover.
10.
Check that all light bulbs are secure in their sockets.
11.
Reconnect power.
B
F
D. UL listed wire connectors
E. White wires
F. Green (or bare) and
yellow-green ground wires
Duct Cover installation (both ducted
and non ducted versions)
1. Assemble the upper duct covers together and install the duct
covers around the support frame. The larger hole in the
flanges of the upper duct cover must be outside the smaller
hole in the mating flange of the other upper duct cover.
NOTE:
For non-ducted (recirculating) installation, the slotted
holes in the upper duct covers will be visible when assembled.
For ducted installations, the slotted holes will be hidden down
inside the lower duct covers.
Remove the film from the duct covers.
A
B
A. 3.5 x 6.5 mm screws (2)
B. 2.9 x 3 mm screws (2)
C. Assembly holes (larger hole outside of smaller hole on both sides)
NOTE: The upper grid orientation belongs to the recirculating version.
9
C
A
B