BONFIGLIOLI Vectron ACTIVE CUBE Guia De Inicio Rapido página 82

Ocultar thumbs Ver también para Vectron ACTIVE CUBE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

8.6
Sizes 3 and 4 ACU401 (5.5 to 15.0 kW, 400 V)
Type
ACU401
Size
Output, motor side
Recommended motor shaft power
Output current
Long-term overload current (60 s)
Short-time overload current (1 s)
Output voltage
Protection
GB
Rotary field frequency
Switching frequency
Output, braking resistor
Min. braking resistance
Recommended braking resistor
(U
= 770 V)
dBC
Input, mains side
2)
Mains current
Mains voltage
Mains frequency
Fuses
UL type 600 VAC RK5
Mechanical
Dimensions
Weight approx.
Ingress protection rating
Connection terminals
Form of assembly
Ambient conditions
Energy dissipation (2 kHz switching
frequency)
Coolant temperature
Storage temperature
Transport temperature
Rel. humidity
If required by the customer, the switching frequency may be increased if the output current is reduced at the same time. Com-
ply with the applicable standards and regulations for this operating point.
Output current 4)
Frequency inverter nominal power
5.5 kW
7.5 kW
1)
9.2 kW
11 kW
15 kW
1)
Three-phase connection requires a commutating choke.
2)
Mains current with relative mains impedance ≥ 1% (see chapter„Electrical installation")
3)
Reduction of switching frequency in thermal limit range
4)
Maximum current in continuous operation
82
-19
P
kW
5.5
I
A
14.0
I
A
21.0
I
A
28.0
U
V
-
-
f
Hz
f
kHz
R
Ω
48
R
Ω
80
I
A
14.2
U
V
f
Hz
I
A
16
I
A
HxWx
mm
D
m
kg
-
-
2
A
mm
-
-
P
W
145
T
°C
n
T
°C
L
T
°C
T
-
%
2 kHz
14.0 A
1)
18.0 A
23.0 A
25.0 A
1)
32.0 A
Quick Start Guide ACU 201, ACU 401, ACU 501, ACU 601
-21
-22
3
7.5
9.2
18.0
22.0
26.3
30.3
33.0
33.0
Maximum input voltage, three-phase
Short circuit / earth fault proof
0 ... 599, depending on switching frequency
2, 4, 8, 12, 16
48
48
58
48
1)
15.8
20.0
320 ... 528
45 ... 66
25
20
250x100x200
3.0
IP20 (EN60529)
0.2 ... 6
vertical
200
225
0 ... 40 (3K3 DIN IEC 721-3-3)
-25 ... 55
-25 ... 70
15 ... 85, not condensing
Switching frequency
4 kHz
8 kHz
14.0 A
14.0 A
1)
1)
18.0 A
18.0 A
3)
3)
22.7 A
22.0 A
25.0 A
25.0 A
1)
1)
32.0 A
32.0 A
-23
-25
4
11.0
15.0
3)
25.0
32.0
37.5
44.5
50.0
64.0
32
32
48
32
1)
26.0
28.2
35
30
40
250x125x200
3.7
0.2 ... 16
240
310
12 kHz
16 kHz
11.8 A
9.5 A
1)
15.1 A
12.2 A
3)
18.5 A
15.0 A
21.0 A
17.0 A
1)
26.9 A
21.8 A
05/16
1)
3)

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acu401

Tabla de contenido