Warning And Error Messages During Operation; Output Current - BONFIGLIOLI Vectron ACTIVE CUBE Guia De Inicio Rapido

Ocultar thumbs Ver también para Vectron ACTIVE CUBE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7.1

Warning and error messages during operation

The code displayed via parameter
A0088 signals warnings A0008 + A0080, for example.
Key
A0000
No warning present.
A0001
Frequency inverter overloaded, warning code (A0002 or A0004)
A0002
Frequency inverter overload (60 s). Check load behavior.
A0004
Short-term overload (1 s). Check motor and application parameters.
A0008
Max. heat sink temperature reached, check cooling system and fan.
A0010
Max. interior temperature reached, check cooling system and fan.
A0020
Speed set point is limited by a controller.
A0080
Max. motor temperature reached, check motor and sensor.
A0100
Mains phase failure, check mains fuses and supply cable.
A0400
Limit frequency reached; output frequency is limited.
A4000
DC link voltage has reached the type-specific minimum.
A8000
Application-specific warning: For detailed functions, refer to Operating Instructions.
Current Error
The error message can be acknowledged via the control unit buttons and STO input.
Key
F00
00
No fault has occurred.
F01
02
Frequency inverter overloaded (60 s), check load behavior
03
Short-term overload (1 s), check motor and application parameters
F02
00
Heat sink temperature too high, check cooling system and fan.
01
Temperature sensor defective or ambient temperature too low.
F03
00
Interior temperature too high, check cooling system and fan.
01
Interior temperature too low, check control cabinet heating.
F04
00
Motor temperature too high or sensor defective, check connection S6IND.
03
Phase failure, check motor and wiring.
F05
00
Overloaded, check load situation and ramps.
03
Short circuit or earth fault, check motor and wiring.
05
Asymmetric motor current, check current and wiring.
06
Motor phase current too high, check motor and wiring.
07
Message from phase monitoring, check motor and wiring.
F07
00
DC link voltage too high, check deceleration ramps and connected brake resistor.
01
DC link voltage too low, check mains voltage.
02
Mains failure, check mains voltage and circuit.
03
Phase failure, check mains fuse and circuit.
04
Mains voltage UDC too high when turned on, check voltage.
05
Mains voltage BC too high when turned on, check voltage.
06
Mains voltage MC too high when turned on, check voltage.
05/16
Warnings
Warning messages
259 and
310 make troubleshooting easier, an error code is displayed.
Last Error
Error messages
Meaning
Overload
Heat sink
Interior
Motor connection

Output current

DC-Link Voltage
Quick Start Guide ACU 201, ACU 401, ACU 501, ACU 601
269 can be composed of several messages. Key
Meaning
GB
73

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acu401

Tabla de contenido