SICK FLOWSIC600 Instrucciones De Servicio página 117

Caudalímetro ultrasónico de gas para transferencia fiscal y aplicaciones en procesos
Ocultar thumbs Ver también para FLOWSIC600:
Tabla de contenido

Publicidad

Apéndice
Figura 46
Código de la clave común (para la descripción breve del diseño del contador de gas, indicado en la placa de
características* y la hoja de datos del instrumento **)
Group
Key code
FL600-
1
METER BODY
Path configuration
1-Path
2-Path
4-Path
1+1-Path redundant
2+2-Path redundant
4+4-Path (Quatro)
4+1-Path (2plex)
2-Path crossed
4-Path crossed
2
Overall length
2D (at meters >24")
3D (standard length)
5D
Shortened Meter body
Other size
3
Nominal size
2" / DN 50
3" / DN 80
4" / DN 100
6" / DN 150
8" / DN 200
10" / DN 250
12" / DN 300
16" / DN 400
Other size
4
Connection flange type
ANSI CLASS 150
ANSI CLASS 300
ANSI CLASS 600
ANSI CLASS ???
DIN/ISO PN16
DIN/ISO PN 63
DIN/ISO PN 100
DIN/ISO PN ???
Inner diameter
5
Schedule 40 (ANSI)
Schedule 80 (ANSI)
Schedule ??? (ANSI)
Specified in [mm] (DIN)
6
Flange type / sealing face
Raised Face (ANSI B16.5)
Ring Type Joint (ANSI B16.5)
Glatt Form C (DIN 2526)
Glatt Form E (DIN 2526)
Form B1 (EN 1092-1)
Form B2 (EN 1092-1)
Special design
7
Material
Carbon Steel (1.1120 / ASTM A216 Gr. WCC )
Stainless steel (1.4408 / ASTM A351 Gr. CF8M)
LT-CS (1.6220 / ASTM A352 Gr. LCC)
Duplex (1.4470 / ASTM A995 Gr. 4A / UNS J92205)
Superduplex (1.4469 / ASTM A995 Gr. 5A)
Superaustenit (1.4557 / ASTM A351 Gr. CK-3MCuN)
Aluminium
8
Connection for Extraction Tool
Yes
No
9
ULTRASONIC TRANSDUCER
10
SIGNAL PROCESSING UNIT - Ex-proof design
Without Ex
CSA Group D T4
CSA Group B, C, D T4
ATEX IIA T4, M20x1.5
ATEX IIC T4, M20x1.5
ATEX IIA T4, 1/2 NPT
ATEX IIC T4, 1/2 NPT
Power supply
11
12 ... 24V DC
Data outputs
12
Hardware variant 1 (4 digital outputs)
Hardware variant 2 (1 analog current output and 3 digital outputs)
Hardware variant 3 (with integrated volume corrector, p- and T-transmitters internally power supplied)
Hardware variant 4 (1 analog current output and 2 RS485)
Hardware variant 5 (with integrated EVC, p- and T-transmitters externally power supplied, I/O board with DSP)
Hardware variant 6 (with integrated EVC, p- and T-transmitters internally power supplied, I/O board with DSP)
Hardware variant 7 (same as hardware variant 1, but with LowPressureAnalogBoard)
Hardware variant 8 (same as hardware variant 2, but with LowPressureAnalogBoard)
Hardware variant 9 (same as hardware variant 4, but with LowPressureAnalogBoard)
Hardware variant A (same as hardware variant 5, but with LowPressureAnalogBoard)
Hardware variant B (same as hardware variant 6, but with LowPressureAnalogBoard)
HART-Protocol (By selection of hardware variant 2 and 8 only)
13
Yes
No
14
Front panel
LED SICK
LCD SICK
15
Custody Transfer design
Yes
No
Rev. 1.10
* Véase → pág. 142, Figura 64
** La hoja de datos del instrumento está incluida en el informe de datos del fabricante (MDR).
FLOWSIC600 · Instrucciones de servicio · 8013761 V 3.0es1 · © SICK AG
1
2
3
4
1
P
2
P
4
P
1
R
2
R
4
R
5
C
2
X
4
X
2 D
3 D
5 D
S D
X D
0 2
0 3
0 4
0 6
0 8
1 0
1 2
1 6
X X
C
L
0
C
L
0
C
L
0
C
L
X
P
N
0
P
N
0
P
N
0
P
N
X
(Will be selected by SICK on the basis of the technical data )
5
1
5
0
3
0
0
6
0
0
X
X
X
0
1
6
0
6
3
1
0
0
X
X
X
S
C
0
0
4
0
S
C
0
0
8
0
S
C
X
X
X
X
X
X
X
.
X
X
6
7
8
9
10
-
-
R F
R
J
G C
G E
B 1
B 2
X X
0
1
2
3
4
5
6
Y
N
_
_
0
1
2
3
4
5
6
11
12
13
14
15
D
C
1
2
3
4
5
6
7
8
9
A
B
Y
N
0
1
Y
N
117

Publicidad

Tabla de contenido
loading

Tabla de contenido