The Check Configurations are defined below.
NOTE: Default settings are in bold.
CONFIGURE ITEM
OPTION
Check Mode
Weighing/Counting
Auto Tare
Off/On/Accept
Accumulate
Off, Manual, Automatic
Audible Signal
Off/Under and
Over/Accept/Under/Over
Auto Opt.
Off/On
Opt. Beep
Off/On
APW Auto Save
Off/On
INPUT/OUTPUT (I/O) SETUP
The I/O setup can be customized for various
user preferences. The I/O setup is defined below.
NOTE: The I/O's will only work when the I/O
option board has been installed. The I/O option
board provides two isolated inputs and four
dry-contact normally open relay outputs which
can be used for simple process weighing.
ITEM
AVAILABLE SETTINGS
Enable
On, Off
Discrete Input 1
Off, Zero, Tare, Clear Tare, Print, Unit, Accumulate
Discrete Input 2
Off, Zero, Tare, Clear Tare, Print, Unit, Accumulate
Discrete Output 1
Off, Under, Over, Accept, Under/Over
Discrete Output 2
Off, Under, Over, Accept, Under/Over
Discrete Output 3
Off, Under, Over, Accept, Under/Over
Discrete Output 4
Off, Under, Over, Accept, Under/Over
PAGE 18 OF 101
APPLICATIONS CONTINUED
DESCRIPTION
Weighing: Check weighing mode
Counting: Check counting mode
Off: Auto tare is turned off.
On: The first stable weight (>=5d) will be tared as a container automatically.
Accept: If object weight is in the range of the Over and Under Limit you set, auto tare will
be performed.
Off: The icon "Σ" does not display.
Manual: The softkey "Σ" displays. User can press the key to accumulate the stable weight.
Automatic: The icon "Σ" displays. The weight will be accumulated automatically.
NOTE: The load to be accumulated has to be >= 10d. The
next accumulation can only start once the pan is cleared.
When LFT is ON (no such limit when LFT is OFF or the approved mode is OIML),
a. Gross weight and net weight cannot be accumulated;
b. Gross 0 has to be reached before a new sample accumulation.
When LFT is OFF,
a. Gross weight and net weight can be accumulated;
b. A new sample can be accumulated after reaching gross 0 or net 0.
Off: No beep.
Under and Over/Accept/Under/Over: Beep when reaching the selected check point.
Off: Auto Opt. is off.
On: The APW will be optimized automatically during count weighing.
Off: Opt. Beep is off. On: When the APW is optimized, the beeper will beep once.
Off: APW Auto Save is off.
On: If the APW is obtained from sampling, and a counting library is selected, the new
APW will save to library after optimized.
1.
2. With the button corresponding to the ▼ icon, go
3. In the Application
4. Select the list item
Press the
button
User
Menu
to enter the Main Menu.
down the list and highlight Application Mode. Enter
this submenu by pressing the button corresponding to
the
icon. (See Figure 62)
mode menu, enter
Check submenu. The
Check submenu is now
displayed. (See Figure 63)
and press the softkey
corresponding to the
icon to change
setting. (See Figure 64)
Figure 62
Figure 63
Figure 64