EN
Simply remove the cap (2) to reach the pressure re-
ducer. The pressure reducer is set to a back pressure
of 4 bar at the factory. To change the back pressure,
loosen the locking screw (10) and turn the rotary
knob (11). The back pressure can be changed by
turning the setting knob (11) (control range 2 - 6
bar).
Clockwise rotation = higher back pressure.
Anti-clockwise = lower back pressure.
The manometer (5) displays the back pressure. Du-
ring setting, an outlet valve downstream from the
pressure reducer must be briefly opened and closed
again a number of times. When water is removed,
the back pressure is temporarily reduced. The back
pressure must not exceed 80 % of the response pres-
sure of the hot water safety valve (DIN 1988-200).
6.2 Insert batteries in the
filter change display (7):
For impeccable, hygienic
enjoyment of drinking water
in accordance with the stan-
dards, the filter fabric must
be replaced at least every
6 months. The installed LED
display gives a timely war-
ning by means of a visual si-
gnal. The supplied batteries
must be inserted for commis-
sioning:
- Remove the cap (2)
- Open the battery com-
partment cover using a
screwdriver
- Insert the batteries (2
x AAA): an automatic
function test occurs (5 x
slow flashing)
- Close battery compart-
ment and replace cover
-
The filter is now ready
for operation.
16
7. Operation
The filter and pressure regulation functions work
completely autonomously without the need for ope-
ration. For impeccable, hygienic enjoyment of drin-
king water in accordance with the standards, it is
only necessary to replace the filter element at least
every 6 months. The integrated LED display gives a
timely warning by means of a visual signal: the red
LED flashes every 5 seconds.
- Flashing interval after 6 months/ 182 days have
elapsed: a red LED flashes every 5 seconds.
- Flashing period: after expiry of time until filter
change or reset occurs.
7.1 Replace filter and check batteries
With the new single lever operation, replacing the
filter element is easy and only takes seconds:
1. Slowly unlock the stopcock (6), thus
simultaneously and automatically stopping
the water (A1).
A1
2. Lift the single lever to approx. 130° (B1) – Pull
out the supporting core, incl. filter cup and filter
element (C1).
B1
C1