Overview Of Installer Selectable Features Which May Aff Ect The Operation Of Your Thermostat - Danfoss TP9000 Guia Del Usuario

Ocultar thumbs Ver también para TP9000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

0:45
45 mins, warm air system poorly insulated building.
1:00
60 mins, radiator system, light weight well insulated building.
(Factory setting)
1:15
75 mins, radiator system, light weight medium insulation.
1:30
90 mins, radiator system, medium weight poorly insulation.
1:45
105 mins, radiator system, heavy weight building, well
insulated.
2:00
120 mins, radiator system, heavy weight building, poorly
insulated.
Option 13 - Optimum start control/Delayed start event setting
(Option 11 set to 1 or 2)
The Optimum start or delayed start control can
be applied to event 1 only or to each event of the
day which requires a higher temperature than
the previous event. Press + until Option 13 is
displayed, use Λ and V to select required setting
(only active if Option 11 is set to 1 or 2).
Setting 0 Applies only to fi rst event of day. (Factory setting)
Setting 1 Applies to each event of the day that requires a higher
temperature compared to previous event.
4.2 Overview of installer selectable features
which may aff ect the operation of your
thermostat
Temperature range limitation
This allows the installer to programme both upper and lower
temperature limits. It may limit the upper and lower temperature
that you are able to set on the thermostat.
Temperature override limitation
This allows the installer to limit the number of degrees that you can
override the programmed temperature by, it also allows the installer
to set rules regarding how long a temperature override will remain
in place.
Danfoss Heating
All manuals and user guides at all-guides.com
GB
GB
PL
GR
ES
23

Publicidad

Tabla de contenido
loading

Tabla de contenido