Operating status
Red LED flashes
Signal tone sounds six
times and red LED flashes
Red LED lights up and
signal tone sounds six
times
Pressing tool stops and no
LED lights up

Maintenance schedule

Interval
Regularly
20
Operating instructions ECO 201
Cause
Actions
Start button was
• Press start button again: Roller drive moves to
released too soon
• Repeat the pressing operation: Press the start
Stop button was
• Press stop button again
pressed or pressing tool
• Press start button: Roller drive moves to its
was not in starting
position
• Repeat the pressing operation
Pressing tool is
• Press stop button
overloaded. The
• Press start button
pressing systems
• Only process permitted pressing systems, see
processed were not
approved
• Repeat the pressing operation
Mains voltage is too low • Check the mains power
• Fully unreel the cable drum of the extension
• If using several extension cables: Reduce
Pressing tool is faulty
• Press the stop button after a power failure
• Press start button
• If this is not successful, send the pressing tool
Power failure
• Press stop button
• Press start button: Roller drive moves to its
• Check the pressfitting for leaks and repeat the
An inspection sticker on the pressing tool indicates the date when the
next service is due. The pressing tool must always be taken for
maintenance together with the pressing jaws in its transport case.
For information about authorised specialist workshops, please
contact your responsible Geberit sales company directly or visit
www.geberit.com.
Maintenance work
• Check the pressing tool and mains cable for externally visible defects
and damage that could affect safety
• Clean and lubricate the pressing tool
• Clean and lubricate pressing jaws/adapters and pressing collars/
MapressMAM jaw adapters: see operating instructions of the particular
system